4. Installing the MultiHaul™ TG Units
To weatherproof the cables:
1.
Thread the connectorized
cable through the lock and
shell, and plug it into the
corresponding port.
2.
Tighten the shell to the unit
firmly by hand (do not use
tools).
3.
Pick a rubber gasket
matching the cable diameter
and insert the gasket snugly
into the shell.
4.
Secure the connector lock (do not use tools).
5.
Attach the cable to the lock with
two cable ties
.
4.8.4
Grounding MultiHaul™ TG Units
1.
Connect one end of the grounding cable to the ground lug terminal.
Secure the screw.
2.
Connect the other end of the grounding cable to the ground connection. If the ground connection is out of
reach of the grounding cable, install a longer cable using 16 AWG grounding cable minimum or according to
local electrical code.
To avoid accidental damage to the connector, unlock the lock before removing the
shell.