This document is proprietary and confidential. No part of this document may be disclosed in any manner to a third party without prior
written consent. © Siklu Communication Ltd 2021 All rights reserved.
25
4. Installing the MultiHaul™ TG Units
4.8.2
Connecting the Cables to the MultiHaul™ TG TU
The MultiHaul™ TG TU includes the following ports on the connector panel under the TU, as shown and described
below:
Port
Connector
Type
Description
ETH1
RJ45
•
10 GbE (2.5/1 GbE)
•
PoE in
ETH2
RJ45
•
1 GbE
(T265-CCP only)
•
PoE out
ETH3
SFP+
•
1 GbE
(T265-CCP only)
•
10 GbE
Use only Class 1 Laser SFP with rated voltage of 3.3 Vdc which is safety
approved to UL/EN/IEC 60950-1 and which is CDRH registered.
AUX
USB
For future use
4.8.3
Weatherproofing the Cables
Before connecting a cable to a unit, you must first enclose the cable connector in a protective all-weather shell. Up
to two sets of all-weather shells are provided with the unit. Additional all-weather shells can be purchased from
Siklu or your reseller (P/N EH-AWS-SHORT).
The provided protective all-weather shells fit cables from 3.5 mm to 9.0 mm in diameter.
In some installations, the cables to the units are protected inside a 3/4" flexible conduit. Siklu provides an adapter
to maintain the Ingress Protection (IP) rating of the installation by matching the all-wather shell termination to a
Liquid Tight Adaptor (LTA) of your choice. The adapter can be purchased from Siklu or your reseller (P/N EH-AWS-
ADAPT-CNDUIT).