This document is proprietary and confidential. No part of this document may be disclosed in any manner to a third party without prior
written consent. © Siklu Communication Ltd 2021 All rights reserved.
13
4. Installing the MultiHaul™ TG Units
4.
Installing the MultiHaul™ TG Units
This section describes how to install the MultiHaul™ TG nodes and TUs.
4.1 Preparing the Site
Carefully select and prepare each site to make installation and configuration as simple and trouble-free as possible.
During site selection and preparation, take into account local safety regulations and consider the long-term needs
of both your network and your applications.
4.1.1
Physical and Environmental Requirements
Each site should meet the following requirements:
•
There must be a clear, unobstructed line-of-sight between the units.
•
MultiHaul™ TG units should be mounted on a fixed, stable, permanent structure. Units can be mounted using
the following methods:
•
On reinforced steel mounting poles with the following diameters:
•
Node - 1.5" - 12"
•
TU - 1.5" - 4"
•
Directly on a wall using the AX-MK-WM accessory, ordered separately from Siklu or your reseller.
Do not mount a MultiHaul™ TG unit on a structure that is temporary or easily
moved. Doing so may result in poor service or equipment damage.
Installation and maintenance of the MultiHaul™ TG link should only be done by service
personnel who are properly trained and certified to carry out such activities.
L'installation et l'entretien d’une unité MultiHaul™ TG ne doivent être effectués que par
du personnel de service qui sont formés et accrédités pour mener à bien ces activités.
Minimum safe distance from antenna while radiating is 29.75 cm / 11.7 in (general
public) or 13.3 cm / 5.2 in (occupational) (according to calculation done based on
"Environmental evaluation and exposure limit according to FCC CFR 47part 1, 1.1307,
1.1310; RSS-102, Safety Code 6).
Distance de sécurité minimum de l'antenne rayonnante est 29.75 cm (selon le calcul fait
sur la base de "l'évaluation environnementale et la limite d'exposition en accordance
avec FCC CFR 47 part 1, 1,1307, 1,1310, RSS-102, CODE 6 sécurité).
2" - 4" poles are recommended, in which case you can use the provided self-
locking bands.