EtherHaul™ 8000 Installation, Operation and Maintenance Manual
Page 27
When connecting the radio to a MAINS DC distribution system, use a 2A circuit
breaker to enable the central DC system to isolate the radio in an emergency
case.
Use one poly circuit breaker and should connect it on the live voltage: (+) or ( -).
The other poly should be grounded.
Connect the circuit breaker to the (+) or (-) live voltage.
The DC input is floating, so either (+) or (-) can be connected to the GND on the
power supply side. For the sake of consistency with other systems, we
recommend that you connect the (+) to the GND.
Use a two-wire cable (14-18 AWG) to connect the power supply to the radio. On
the radio DC terminal, connect the (+) and (-) wires to the correct ports.
Caution:
Use DC power supply which is safety approved to UL/EN/IEC 60950-1 with rated
voltage of 42-57 VDC and rated current of 2A max
Figure 2-8 DC Terminal Block
Use screwdriver to tight and lock the connector’s locking bolts.
2.8.1.2
PoE Power
Connect Power over Ethernet (PoE) to port Eth1 only.
The PoE power range of the unit is 42-57V.
The power source should be limited to 1.4A to avoid surges and possible damage
to the radio.
Caution:
Use a PoE power supply which is safety approved to UL/EN/IEC 60950-1 as a limited
power source (LPS) with rated voltage of 42-57 VDC and rated current of 1.4A max