VO 

Installation and operating of the measuring chamber housing  

Technical changes reserved 

 

- 43 -

 

4

 

Installation and operating of the measuring chamber housing 

 

Before installing the device, check that 

 

the pressure bearing parts have not been damaged during transportation 

 

the wetted materials of the device are suitable for the media being used (

 § 10.1 

"Wetted parts' materials"). 

 

the equipment is switched off and is in a safe and de-energised state. 

 

the equipment is depressurised and has cooled down. 

 

SUITABLE TOOLS: 

 

 

Use only suitable tools of the correct size. 

 

 

4.1

 

Installation instructions  

Please observe the following installation instructions: 

 

Only trained personnel who have been authorized by the system operator are allowed to 
perform assembly, electrical installations, commissioning, maintenance and operation. 
You must have read and understood the instructions and follow their instructions strictly.  

 

Our oval gear flow meters are precision flow meters. Inlet and outlet are covered with 
protective caps against foreign substances.  
Remove caps shortly before putting the device into operation.  

 

As indicated on the type plate parameters are maximum values and must not be exceed-
ed. Operating parameters are specified in the contract documents. Use with other opera-
tional data only after consultation and stating the order number. 

 

Install the oval gear flow meter in the pressure pipe behind the pump (approximately 3 m 
liquid column pressure drop for nominal flow rate)  

 

Pay attention to the tightening torque (

 § 10.1.1 "Tightening torque") of your VO while 

tightening the process connection (thread, flange). 

 

Install the oval gear flow meter in such a way, that it remains filled with liquid also in 
non-operating condition. 

 

To avoid measuring inaccuracies due to gas bubbles or contamination, preventive 
measures must be taken (e.g. gas separator or type N strainer)  

 

Oval gear flow meters intended for liquid food products must be cleaned thoroughly be-
fore putting them into operation (

 § 8.1 "Maintenance and cleaning").  

 
 

 

Содержание VO 015

Страница 1: ...the appliance is resold please provide the operating manual along with it SIKA Ba_VO 06 2015 Oval gear flow meters VO Types VO VA VO VP VO AP Sizes 015 06 1 2 5 10 50 115 Operating manual Translation...

Страница 2: ...ey functions in normal mode 50 6 3 Operating menu 50 6 4 Open collector pulse output displays 2 and 3 56 6 5 Level and parameter operating menu 57 7 Problems 59 8 Maintenance cleaning repairs hazardou...

Страница 3: ...of injury This sign indicates dangers that cause personal injuries that can lead to health defects or cause considerable damage to property CAUTION High temperature This sign indicates dangers result...

Страница 4: ...Electronics with display or pulse sensors M12x1 without illustration Upper housing part Process connections input and output side Lower housing part Cable gland displays 1 2 Oval wheels Gasket Versio...

Страница 5: ...s for completeness Compare the device data with the data on the delivery note and in the order records Device 1x VO according to the order data 2x Process connection protective caps 1x Operating manua...

Страница 6: ...he VO as a safety component The operational safety of the device supplied is only guaranteed by intended use The speci fied limits 10 Technical data may under no circumstances be exceeded Before order...

Страница 7: ...on This can be based on training or relevant tuition The personnel must be aware of this operating manual and have access to it at all times General safety instructions In all work the existing nation...

Страница 8: ...to the measuring chamber wall the input side is separated and sealed from the out put side Between the individual oval wheels and the adjacent measuring chamber wall a movable measuring chamber is fo...

Страница 9: ...ur oval gear flow meters are precision flow meters Inlet and outlet are covered with protective caps against foreign substances Remove caps shortly before putting the device into operation As indicate...

Страница 10: ...ratures Make sure that the installation has cooled down before mounting dismounting Remove any impurities from the pipe work Flush the pipeline when doing so replace the VO with a suitable piece of pi...

Страница 11: ...that are supplied with calibration you receive a test certificate with your device the device specific pulse factor K factor in pulses per litre will be listed This K factor is also specified on the d...

Страница 12: ...ctrical system before connecting the VO 5 2 1 Sensor For connection to evaluation electronics or a PLC or of the user sensor must be powered with 10 30 VDC 3m connection with PVC cable 3 x 0 34 mm 2 L...

Страница 13: ...nd the operating mode A sliding switch A B is provided on the connec tion circuit board for this purpose An external sensor with a cable length of up to 30m can always be connected at terminals 1 and...

Страница 14: ...d to the oval gear flow meter Remove the con nector from the electronics 2 Place the electronics with the display facing downwards on a suitable surface Unscrew the 4 crosshead screws on the underside...

Страница 15: ...tatuses sensor signals pro gramming symbols etc Use the key to select the display Q V1 V2 Q V1 V2 Explanation of the display symbols A or B is displayed for approx 0 5 s when a pulse is generated at t...

Страница 16: ...the key to set the units kg t l or m Once the desired unit has been set press the key to save it Level 6 K Factor The K factor is displayed as 0660 0000 This needs to be changed to 0200 000 The first...

Страница 17: ...w zero is impossible the smallest value that can be displayed at the volume meter is 0 Select operating mode 3 6 3 3 Volume units level 2 The displayed volume unit can be freely selected litters cubic...

Страница 18: ...23 The alpha value is always positive The temperature of the connected PT1000 is recorded and displayed in level 14 The temperature is recorded in 0 5 steps Please observe the permissible temperature...

Страница 19: ...caling Definition of the positions for the following explanations Position 1 far right Position 2 second from right etc Example 1 Setting 1 has been selected in level 24 position 1 Meter reading V1 01...

Страница 20: ...d is preset during production and cannot be changed by the customer The device comes with a printed pro tocol Device Configuration VO Electronics containing all the programmed parameters The password...

Страница 21: ...4 always check and correct the measuring ranges in level 123 and 124 6 3 14 Current simulation level 125 only display 3 Any value between 04 00 and 20 00 mA can be set The set value is output as curr...

Страница 22: ...r voltages of between 5 and max 24 V The cur rent carrying capacity of the output is max 30 mA If a voltage is applied to terminal 5 without resistance the output stage of the electronics will be dest...

Страница 23: ...de 1 A and B at a measuring chamber possibility of return identification 2 A B measurement of the total volume 3 A B measurement of the difference consumption measurement 2 Volume unit Selection of th...

Страница 24: ...perature sensor Factor for density correction 24 Pulse output scaling 0 Original pulses of sensor A pulse duration original pulses 4ms 1 1 pulse per change of the right hand position of V1 right 2 1 p...

Страница 25: ...If the oval gear flow meter will not be in operation for a longer period of time it has to be dismounted thoroughly cleaned and conserved with acid free oil Oval gear flow meters used for liquid food...

Страница 26: ...e if the medium is hazardous to health i e caustic toxic carcinogenic or radioactive etc Please do not return the device if you are not perfectly sure that all media hazardous to health have been clea...

Страница 27: ...steel Aluminium Oval gear Stainless steel PEEK PEEK Bearing Coal PEEK PEEK Axle Stainless steel Stainless steel Stainless steel O ring FKM Standard optional EPDM FEP Process variables Medium to measu...

Страница 28: ...ue Nm Thread Flange 5 5 5 24 35 30 30 55 37 37 60 60 10 1 2 Sensor and display unit Sensor Display 1 Display 2 Display 3 Version Display LCD 8 digit Local on site indication Remote wall mounting Elect...

Страница 29: ...7 245 Bmax D mm 96 101 111 120 125 152 213 271 Installation size mm 73 73 73 90 102 102 184 196 F G G G G G 1 G 1 G 2 G 2 Depending on sensor Process connection flange DIN 1092 1 Form B1 Without displ...

Страница 30: ...Technical data VO 64 SIKA Ba_VO 06 2015 Wall mounting plate...

Страница 31: ...VO Technical data Technical changes reserved 65 10 3Pressure drop...

Страница 32: ...Technical data VO 66 SIKA Ba_VO 06 2015...

Страница 33: ...VO Technical changes reserved 67 For your notes...

Страница 34: ...easuring Instruments Durchflussmesstechnik Flow Measuring Instruments Test und Kalibriertechnik Test and Calibration Instruments SIKA Dr Siebert K hn GmbH Co KG Struthweg 7 9 D 34260 Kaufungen Germany...

Отзывы: