10.1.1
Sizes
Size
VO 015 VO 06 VO 1 VO 2 VO 5 VO 10 VO 50 VO 115
Measuring range [l/min]
-
Oval gear VA
-
Oval gear PEEK
0.03…1
0.03…1
0.2…5
0.2…7
0.4…10
0.4…14
1…30
1…30
2…50
2…60
4…100
3…120
15…300
-/-
35…660
-/-
Pulse rate,
K-factor [1/l]
3100
333
166
100
40
20
4
1.7
Process connection
-
Thread
-
Flange
G¼
-/-
G½
-/-
G½
-/-
G¾
DN 15
G1
-/-
G1
DN 25
G2
DN 50
G2
DN 50
Weight [kg]
Thread:
-
VO…VA
-
VO…VP
-
VO…AP
1.5
-/-
-/-
2.2
1.5
-/-
2.4
1.6
-/-
2.7
1.8
-/-
4.2
-/-
-/-
5.6
3.3
-/-
31
-/-
-/-
55
-/-
-/-
Flange:
-
VO…VA
-
VO…VP
-
VO…AP
-/-
-/-
-/-
-/-
-/-
-/-
-/-
-/-
-/-
6.5
-/-
2.8
-/-
-/-
-/-
15
-/-
6
31
-/-
-/-
55
-/-
-/-
Tightening torque [Nm]
-
Thread
-
Flange
5
-/-
5
-/-
5
-/-
24
35
30
-/-
30
55
37
37
60
60
10.1.2
Sensor and display unit
Sensor
Display 1
Display 2
Display 3
Version
Display
-/-
LCD - 8 digit
Local (on-site indication)
-/-
Remote (wall mounting)
-/-
-/-
Electrical characteristics
Power supply
10…30 V
DC
18…30 V
DC
*
1
Lithium battery
3.6 V
10…30 V
DC
Current consumption
<1 mA
7 mA
100 mA (30 V
DC
)
Signal output
NPN / PNP *
2
-/-
NPN open collector NPN open collector
Analogue 4…20 mA
Electrical connection
Plug M12x1
-/-
Terminal strip
Cable length for wall
mounted
-/-
-/-
2,000 mm
Degree of protection (EN 60529) *
3
IP67 *