— VMZ.2
Device description
Technical changes reserved
- 5 -
Accessories:
Connection cable with moulded M12x1 coupling socket.
M12x1 coupling socket as component.
1.2 Intended use
The magnetic inductive flow sensor VMZ.2 must only be used for measuring and metering
liquids with a minimum conductivity of 20
μ
S/cm.
WARNING! No safety component!
The magnetic inductive flow sensor of the series VMZ.2 is no safety component in ac-
cordance with Directive 2006/42/EC (Machine Directive).
Never use the VMZ.2 as a safety component.
The operational safety of the device supplied is only guaranteed by intended use. The speci-
fied limits (
§ 9 “Technical data”) may under no circumstances be exceeded.
Before installing the device, check that the wetted materials of the device are compatible with
the media being used (
Measuring tube empty (or partially filled). / Conductivity too low.
The green LED may blink irregularly if the measuring tube of the VMZ.2 is empty or par-
tially filled or if the conductivity of the fluid being used is too low. Random pulses will be
present at the output, but they do not represent an actual flow.
Ensure that the measuring tube of the VMZ.2 is always completely filled
(
§ 4.1 “Installation instructions”).
Ensure that the conductivity of the fluid is at least 20
μS/cm.
1.3 Exclusion of liability
We accept no liability for any damage or malfunctions resulting from incorrect installation, in-