HBG 1011
10.4“ HANDHELD CONTROL PANEL
Page 22
16.08.2018
5.2
Key Switch
The key switch is two-stage and read via the SCP XXX connected to the Safety Interface. In
the SCP XXX, the "HGB0811_K class is used; inputs 5 and 6 are assigned to the key
switch.
5.3
Confirmation Switch
The confirmation switch is three-stage. The confirmation switch must be activated with the
key switch, because they are serial. If the switch is not pressed or pressed only partially, it
is inactive. The switch is active when simply pressed (middle stage). In the SCP XXX, the
"HBG 0811
” module is used; inputs 1 and 2 are assigned to the confirmation switch.