10.4“ HANDHELD CONTROL PANEL
HBG 1011
16.08.2018
Page 21
X2:
Cable connector M16
The appropriate connector cables are optionally available.
See documentation for connection cables operating devices.
The
handheld
control
panel
can
only
be
operated
with
the SCP XXX Safety module!
As required by EN ISO 13850, section 4.1 and EN 60204-1, section 10.7.1, it
must be impossible to confuse a functioning handheld control panel with a
non-functioning one.
Note on the Emergency Stop function: A non-connected HBG 1011 does not
have to be visibly sealed!
LED
Pin
Wire color
Function
L
Yellow
Safety Interface-H
J
Green
Safety Interface-L
G
Black
Safety Interface shield
E
Red
+24 V DC
C
Black
GND
A
Shield
HMI-Link shield
U
White
HM
I-
L
ink
D2+
T
Red
D3+
S
Blue
D3
R
Pink
D4
P
Gray
D4+
O
Yellow
D1
N
Green
D1+
M
Brown
D2
LED status
Definition
LED lights green
DC OK