WATCHDOG
The program was interrupted via the
watchdog logic.
Possible Causes:
-
User program interrupts blocked
over a longer period of time (STI
command forgotten).
-
Programming error in a hardware
interrupt.
-
INB, OUTB, INW, OUTW instruc-
tions used incorrectly.
-
The processor is defective.
Solution:
-
Correct programming error.
-
Exchange CPU
06
GENERAL ERROR
General error
An error has occurred while stopping the
application over the online interface.
This error occurs only during the de-
velopment of the operating system.
07
PROM DEFECT
An error has occurred while programming
the memory module.
Causes:
-
The program memory module is
defective.
-
The user program is too large.
-
The program memory module is
missing.
Solution:
-
Exchange the program memory
module
08
RESET
The CPU has received the reset signal
and is waiting for further instructions.
The user program is not processed.
Info
09
WD DEFECT
The hardware monitoring circuit (watch-
dog logic) is defective.
After power-up, the CPU checks the
watchdog logic function. If an error occurs
during this test, the CPU deliberately en-
ters an infinite loop from which no further
instructions are accepted.
Solution:
-
Exchange CPU
10
STOP
The program was stopped by the pro-
gramming system.
11
PROG BUSY
Reserved
12
PROGRAM LENGTH
Reserved
13
PROG END
A memory module was successfully pro-
grammed.
Info
14
PROG MEMO
The CPU is currently programming the
memory module.
Info
Содержание ETT 736
Страница 7: ...TOUCH OPERATING PANEL ETT 736 12 01 2022 Page 5 17 1 Buffer Battery 50 18 Disposal 50...
Страница 21: ...TOUCH OPERATING PANEL ETT 736 12 01 2022 Page 19 5 Interfaces 5 1 Bottom Connections...
Страница 34: ...ETT 736 TOUCH OPERATING TERMINAL Page 32 12 01 2022 10 Process Diagram...
Страница 53: ...TOUCH OPERATING PANEL ETT 736 12 01 2022 Page 51 Documentation Changes Change date Affected pages Chapter Note...
Страница 54: ...ETT 736 TOUCH OPERATING TERMINAL Page 52 12 01 2022...