5.1.3
X4, X5: Ethernet 10/100 (RJ45)
Problems can arise if a control is connected to an IP network, which contains
devices that are not running with a SIGMATEK operating system. With such
devices, Ethernet packets could be sent to the control with such a high fre-
quency (i.e. broadcasts), that the high interrupt load could cause a real-time
runtime error or runtime error. By configuring the packet filter (Firewall or
Router) accordingly, it is possible to connect a network with SIGMATEK hard-
ware to a third-party network without triggering the error mentioned above.
For use in local networks only, not in telecommunication circuits!
5.1.4
X6: CAN (6-pin Weidmüller RM 3.5 not galvanically separated)
Pin
Function
1
Rx+
2
Rx-
3
Tx+
4
n.c.
5
n.c.
6
Tx-
7
n.c.
8
n.c.
Pin
Function
1
CAN A (LOW)
2
CAN B (HIGH)
3
CAN A (LOW)
4
CAN B (HIGH)
5
GND
6
GND