HGW-BWH
CONFIGURATION
8.2.1 Connecting over a Network Interface
To create a connection to the device through a network interface (WLAN or Ethernet), perform
the following steps in LASAL CLASS 2:
1. Open LASAL CLASS 2
2. In the menu tab select the item “tools” -> “Advanced Debug Tools” and open the item
“Diagnosis Tool...”
3. In the “Plc Diagnosis” window that opens, select the item “Change Online Settings”
(see Icon
)
4. A configuration window then opens:
5. With the “New” button, create a new
connection and assign it a unique
name.
6. Ensure that the “Connection Type” is
set to TCP/IP.
7. The password field must remain
empty.
8. Enter the IP address of the device to
configure (see 7 Factory Settings for
the default settings).
9. Close the window with the “OK” button”
10. After successfully defining the connection parameters, the new connection is already
selected in the selection list
(marked in blue)
shown in the “Plc Diagnosis” window. If
not, you can then select it.
11. The Link button (marked red) can now be used to create a connection to the device. If
the connection is successfully created, the display of the switching element changes.
Page 46
17.05.2022
Содержание BWH
Страница 21: ...CONFIGURATION HGW BWH 17 05 2022 Page 19...
Страница 22: ...HGW BWH CONFIGURATION Using the file commander connect to the BWH Page 20 17 05 2022...
Страница 28: ...HGW BWH CONFIGURATION The BWH is now configured Page 26 17 05 2022...
Страница 30: ...HGW BWH CONFIGURATION Next load the process project into the operating device Page 28 17 05 2022...
Страница 31: ...CONFIGURATION HGW BWH The visualization project is now also loaded into the HGW 17 05 2022 Page 29...
Страница 40: ...HGW BWH CONFIGURATION Page 38 17 05 2022...
Страница 41: ...CONFIGURATION HGW BWH 17 05 2022 Page 39...