Translation of the original operating manual
Identifying and adapting incorrectly set rotors
The centrifuge automatically identifies the rotor that is being currently
used.
If the system identifies a different rotor than the one that is set, if
there are no different buckets for this rotor, and if the speed has
not been adapted manually, the rotor input will be adapted
automatically. The system will not display a message.
If the system identifies a different rotor than the one that is set,
and if there are different rotor/bucket combinations for this rotor,
the system will automatically select the rotor with the lowest
speed. The system will display a corresponding message so that
the rotor can be selected manually.
If the system identifies a different rotor than the one that is set, if
the speed has been limited, and if there are no rotor/bucket
combinations, a message will be displayed.
This prevents the maximum permissible speed from being exceeded.
Progr.: Program List
This field in the standard menu shows the program that is currently
loaded. When the field is selected, the program list is displayed (for
information on how to work with the programs, see 6.4.4 "Program
Mode").
The rapid cooling program “RAPID_TEMP“cannot be deleted (see
6.4.3.7"Parameter Menu, Process").
Fig. 6.31: Program selection list