
Laboratory Centrifuge Sigma 3-16L
Laboratory Centrifuge Sigma 3-16L IVD
11 Appendix
58 / 79
Version 03/2014, Rev. 2.11 of 11/08/2017
• sb
Translation of the original operating manual, part no. 0700902
Pos : 203 /100 Sig ma/100 BA Z entrif ugen Sig ma (St andardmodul e)/110 Anhang/ 110 Anhang===================================== @ 28\ mod_1405320699310_68.doc x @ 195069 @ 1 @ 1
11 Appendix
Pos : 204 /100 Sig ma/110 BA Z entrif ugen Sig ma (Proj ekt e)/ 3-16L/110 Anhang/ 110-0010 Zubehörpr ogramm 3-16L @ 29\ mod_1405321662642_68. doc x @ 197309 @ 2 @ 1
11.1 Range of accessories
Part no.
Description
Max. speed
(rpm)
Max.
gravitational
field (x g)
11132
Swing-out rotor 28 x 15 ml complete, no. 11133, incl. 2 sets buckets no.
13104, 2 sets round carriers no. 17015 and 28 PP-tubes 15 ml no. 15023
Radius max. 15.5 cm, radius min. 4.5 cm
5 000
4 332
11133
Swing-out rotor, 4 place, for buckets no. 13104, 13130
5 000
11135
Swing-out rotor 24 x 1.5/2.0 ml, incl. 3 sets buckets no. 13124, for e.g.
reaction vials no. 15008, 15040, incl. hermetic aluminium lid no. 17879
Radius max. 7.4 cm, radius min. 3.5 cm
12 500
12 927
11136
Drum rotor for 6 cassettes no. 14000, 14002, 14020, 14021, for reaction
vials (max. 60/192 pcs.), incl. hermetic aluminium lid no. 17898
Radius max. 7.0 cm, radius min. 3.0 cm
Attention!
The vessels could be damaged at speeds exceeding 13,000 rpm!
13 000
13 226
11180
Swing-out rotor, 4 place, for buckets no. 13180, 13190, 13194
4 200
11181
Swing-out rotor 48 x 15 ml complete, no. 11180, incl. 2 sets rectangular
buckets no. 13180, 2 sets rectangular carriers no. 18015 and 48 PPCO-
tubes 15 ml no. 15023
Radius max. 17.1 cm, radius min. 7.6 cm
4 200
3 372
11182
Swing-out rotor 12 x 50 ml culture tubes complete, no. 11180, incl. 2 sets
buckets no. 13190, 2 sets adapters no. 17346 and 12 tubes no. 15151
Radius max. 17.2 cm, radius min. 7.5 cm
4 200
3 392
11222
Swing-out rotor for microtiter plates, incl. 1 set carriers no. 13222,
max. height of plates 56 mm, max. load per bucket approx. 335 gram
Radius max. 12.1 cm, Radius min. 4.8 cm
3 000
1 218
11224
Swing-out cytology rotor complete, incl. 2 sets buckets no. 13224,
4 inserts no. 15223. The buckets with the object carriers could be locked in
90° position,
Radius max. 11.3 cm, radius min. 6.9 cm
3 000
1 137
11241
Swing-out rotor for microtiter plates, Biosafe with certificate, incl. 1 set
buckets no. 13241, 1 set caps 17108 and plate holder no. 17982, max.
height of plates 55 mm, without cap 17108 max. 66 mm, Max. load per
bucket approx. 290 gram
Radius max. 13.3 cm, radius min. 4.4 cm
4 200
2 623
12111
Angle rotor 10 x 10 ml, for tubes no. 15000, 15010, 15039,
incl. hermetic aluminium lid no. 17835
Radius max. 7.6 cm, radius min. 2.8 cm, angle 35°
15 300
19 890
12115
Angle rotor, for 12 PCR-strips with 8 tubes 0.2 ml, e.g no. 15042,
incl. hermetic aluminium lid no. 17875
Radius max. 9.8 cm, radius min. 7.2 cm, angle 45°
14 000
21 475
12131
Angle rotor 30 x 1.5/2.0 ml, for e.g. reaction vials no. 15008, 15040,
incl. hermetic aluminium lid no. 17848
Radius max. 10.0 cm, radius min. 6.7 cm, angle 45°
13 200
19 480
12150
Angle rotor 6 x 50 ml, for tubes e.g. no. 13055, 15051, 15052,
incl. hermetic aluminium lid no. 17837
Radius max. 8.4 cm, radius min. 2.1 cm, angle 25°
10 000
9 391