4.7.4
Relative To
“Relative to” is used to measure the delta values of X (Frequency or Time) and Y (Amplitude)
between two markers which can mark on different traces.
After the marker selects “Delta”, the original marker will become the delta measurement marker,
and the related marker of the incrementing sequence number will become the reference “fixed”
marker
Command format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:REFerence 1|2|3|4
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:REFerence?
Instructions
Sets/Gets the marker relative to
Parameter type
Enumeration
Parameter Range
1|2|3|4|5|6|7|8
Return
Enumeration
Example
:CALCulate:MARKer1:REFerence 3
4.7.5
Peak->CF
Set the current peak frequency to the center frequency.
4.7.6
Update Peak/Maximum Peak
Searches for
maximum
peaks and marks them with specified cursors.
Command format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:MAXimum
Instructions
Marker searches for maximum peaks and marks them with the specified
marker
(If peak-to-peak value is on, peak-to-peak value search is carried out;
otherwise, single peak value search is carried out)
Example
:CALCulate:MARKer4:MAXimum
Command format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:MAXimum:NEXT
Instructions
Marker searches for the next peak and marks it with the specified marker
Example
:CALCulate:MARKer1:MAXimum:NEXT
Содержание SSA5083A
Страница 1: ...User Manual EN_01A SSA5085A SSA5083A Spectrum Analyzer...
Страница 2: ......
Страница 4: ......
Страница 29: ...User Manual XXV 10 2 TROUBLESHOOTING 225...
Страница 30: ......
Страница 97: ...User Manual 67...
Страница 253: ...User Manual 223 Power SYSTem POWer OFF SYSTem RESTart Buzzer DISPlay WINDow BEEP STATe DISPlay WINDow BEEP VOLUme...
Страница 259: ......