Copyright ©Sigicom AB
37
15. ÖNORM S 9012
Beurteilung der Einwirkung von Schwingungsimmissionen des
landgebundenen Verkehrs auf den Menschen in Gebäuden ―
Schwingungen und sekundärer Luftschall .
Level, frequency ranges:
700 mm/s
2
, RMS 1s, 1-80 Hz
Filtered according to ISO 2631-2.
Max. resolution in presentation: 0.1 mm/s
2
RMS and 3 significant
digits.
Threshold range 1 – 550 mm/s
2
.
Transient file resolution: ~0.04 mm/s
2
.
16. ISO 8569 Accelerometer (Replaces standard 6, if not very small
levels)
Mechanical vibration and shock -- Measurement and evaluation of shock and
vibration effects on sensitive equipment in buildings.
Level, frequency ranges:
125 m/s
2
, 5-300 Hz
Max. resolution in presentation: 0.01 m/s
2
and 3 significant digits.
Threshold range 0.1 – 110 m/s
2
. Transient file resolution: ~0.005 m/s
2
.
Note!
The stated range/resolution in acceleration is only valid at 80Hz
because sensor element measures velocity. At lower frequencies the
range/resolution is scaled down. Above 80Hz, range/resolution is
scaled up.
17. ISO 10816-2
Mechanical vibration -- Evaluation of machine vibration by
measurements on non-rotating parts -- Part 2: Land-based steam
turbines and generators in excess of 50 MW with normal operating
speeds of 1500 r/min, 1800 r/min, 3000 r/min and 3600 r/min.
Level, frequency ranges:
200 mm/s, RMS 1s, 5-500 Hz
Max. resolution in presentation: 0.05 mm/s RMS, and 3 significant
digits.
Threshold range 0.2 – 180 mm/s.
Transient file resolution: ~0.01 mm/s.