18
11. Approximate Valve & Fan Settings
Heater Temperature Fan Knob Position
Cold Start Off
Warm Low Off
Warm Low (cold or windy) 4 to 5 o’clock
Medium 5 to 6 o’clock
Medium (cold or windy) 6 to 7 o’clock
High 7 o’clock
*
Operating the fan can deliver too much air and cause the burner to run too
lean (too much air in the fuel to air mixture). If you find that the flames start
to burn below the top burner ring, turn the fan down slightly or increase the
fuel slightly.
*
The fan has a low amperage motor
and will need to have the speed control
turned up to a faster speed to get the fan blade spinning, then turn it down to
the appropriate setting. This also applies, should the fan blade rattle.
*
The best low speed setting is at the 4 to 5 o’clock position on the speed
control knob. The best medium setting is at the 5 to 6 o’clock position and
the best high setting is at the 6 to 7 o’clock position.
*
When turning up the valve
wait a minute and watch the flames react before
adding air.