-18-
•
Replace the top casting into the bottom casting so the metering stem slides in to
the metering guide.
•
Replace the 4 top screws snugly, and move the control knob up and down while
tightening the 4 screws. Once tight the control knob should move up and down
freely in any position.
•
Meter the valve to the specifications above and check the overflow fuel line ( if
the float is operating correctly and adjusted parallel to the casting the oil level in
the valve will be correct.
The metering screw/high fire screw can also be replaced from the valve rebuild kit, or
kept as a spare.
Kit Includes
(# 905005)
1.
Float
2.
Float pin
3.
Float Bracket
4.
High Temp Fuse c/w metering screw adjustment screw (6-32)
5.
Replacement fuel screen
6.
Viton ‘O’ ring
7.
Needle & seat & copper/brass washer assembly
8.
Adaptor spacer for new style needle and seat
9.
Instructions