SIERRA LIMITED FIVE, THREE, ONE, YEAR LIMITED WARRANTY

Sierra Products, Inc. (SPI), warrants to the original consumer this stove will be free of defective materials and workmanship

for the following periods: 

Outer structure - Limited Five Year, Interior metal construction - Three Years, All other items -

One Year 

from the date of purchase. This warranty does not extend to any parts worn or damaged through normal ware, 

abuse, accident, or neglect or warpage due to over-firing; nor does it apply if the stove has been repaired or modified unless

by SPI written authorization.  If the stove proves to be defective in material or workmanship within the warranty period, SPI

will, at no charge, repair or replace (at its option) any defective parts, if the purchaser ships the parts or the stove, freight

prepaid, to SPI or the nearest authorized service center.  SPI may require the consumer to supply reasonable proof of the

stoves purchase date.

This warranty is in lieu of any other express warranty.  Any implied warranties, including but not limited to any

implied warranty of merchantability or fitness for a particular purpose shall not extend beyond one year from the

date of purchase.

The purchaser's sale and exclusive remedy shall be for the repair or replacement of defective parts, as provided for in this

warranty.  No other remedy (including but not limited to incidental or consequential damages for lost profits, lost sales, injury

to person  or property, or other incidental or consequential loss) shall be available to the purchaser.

Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or

limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.

SPI's warranty obligation and the purchaser's rights under it can be altered only by a subsequent written agreement

between SPI and the purchaser.

The remedies provided in this warranty are void unless the attached warranty registration card is received by SPI within

30 days from the date of purchase.

If you have a warranty claim or questions about the performance of your stove, you are requested to contact your dealer. 

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Please fill out and return the

bottom half of the page to: 

SIERRA PRODUCTS, INC.

63 Laxalt Dr.

Carson City, NV 89706

Form: Sierra Wood Stove Warranty 2021.wpd

Содержание S8000II

Страница 1: ...ion and operation of the Sierra S8000II wood heater EMISSION CERTIFICATION STATUS The S8000II model meets the U S Environmental Protection Agency s emission limits New Source 2020 ASTM E3053 2017 and EPA Alternate Test Method ATM 125 for cordwood Under specific test conditions this heater has been shown to deliver heat at rates ranging from 16 700 to 71 300 Btu hr capable of heating approximately ...

Страница 2: ... heater design specifications can result in permanent damage to the heater A glowing stove or connector pipe is hazardous HEARTH PROTECTION Floor protection and or hearth extension is required for the Sierra Stove All floor protection materials must be non combustible i e metals brick stone mineral fiber boards etc Floor protector must be a 1 2 minimum thickness non combustible material having an ...

Страница 3: ...ve door and bottom air control The fire should die down once deprived of oxygen If the fire doesn t die call the fire department for assistance CAUTION In airtight stoves after closing the bottom air control volatile gases are still given off by the wood smoldering in the firebox A sudden burst of oxygen caused by opening the draft control or door while stove is smoldering will ignite the volatile...

Страница 4: ...placed before using 7 The chimney should be the proper size Some fireplace chimneys are quite large and will cause poor stove performance and excessive creosote The rule of thumb is that the chimney flue should be roughly no more than three times the flue opening on the stove A 6 inch stove flue will work in an 8 inch by 12 inch fireplace flue It may be necessary to install another liner in an ove...

Страница 5: ...e thickness with a ventilated thimble minimum 24 gauge in thickness having two 1 inch air channels separated from combustibles by a minimum of 6 inch of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Solid insulated listed factory build chimney length with an inside diameter 2 inch larger than the chimney connector a...

Страница 6: ...tween the stove and an approved chimney but never as the chimney itself To minimize creosote formation in the chimney connector pipe place stove as close to the chimney as safety clearances will allow Never use more than two elbows Any horizontal pipe section should rise 1 4 per foot towards chimney This will allow creosote to run back into the stove Special methods are required when passing a chi...

Страница 7: ... follow this procedure 1 Convent specifications to R value a R value is given no conversion is needed b K factor is given with a required thickness T in inches R 1 k T c C factor is given R 1 C 2 Determine the R value of the proposed alternate floor protector a Use the formula in step 1 to convert values not expressed as R b For multiple layers add R values of each layer to determine the overall R...

Страница 8: ...tion or sections of stove connector pipe that connect the stove flue outlet to the fireplace chimney Method I is normally used and is generally the easiest to install Method II may be used in chimneys that need a new flue liner 8887 There are qualified installers in most areas that can install your stove for you Sierra recommends that you contact the National Chimney Sweep Guild for a member in yo...

Страница 9: ...a 30 minimum clearance between mantel and stove top If less clearance is needed there are approved mantel shield kits available so check with your Sierra dealer 6 The Sierra Fireplace Cover Kit FPCK may be used to enhance the looks of the hearthstove installation but it is not required with the direct connection method of installation Instructions for installation are supplied with this kit THE FP...

Страница 10: ...ur stove has a blower do not run the electrical cord in front or near the fire box V USING A CATALYTIC COMBUSTOR Definition and Purpose of a Catalytic Combustor Catalytic combustors for woodstoves cats are simular in principle to catalytic converters on automobiles The big difference is that the heat generated by your woodstove is put to use heating your home instead of being dumped out the tailpi...

Страница 11: ... firebox heat and coal bed for the large long burn load Kindling Made from small pieces diameter and 6 12 long A hatchet works well for splitting a small piece of cord wood length wise You ll need about 4 lbs of kindling to heat up the flue and start a small draft Starting Load Made up of 2 diameter pieces 12 16 long You ll need about 6 lbs of start up fuel to build the coal bed and warm up the st...

Страница 12: ...the bottom of the firebox This allows the air to get under the fire better 3a High Altitude Starting Instructions Follow all steps above l through 3 however due to the decreased density of oxygen supplied in a given volume of air at higher elevations it will be necessary to allow the stove to burn for a longer period of time with the air control rod pulled all the way out It may also be necessary ...

Страница 13: ...t or oxygen present in the stove this wet and steamy smoke does not ignite and burn Instead it is drawn through the exhaust vent and into the chimney As this steam begins to cool down in the flue it condenses as droplets of moisture on the inside walls of the chimney This becomes creosote which is flammable and is the fuel which burns in a flue fire It is necessary to periodically clean these depo...

Страница 14: ...re 4 If you do have a chimney fire call the fire department immediately Only then attempt to control the fire Throw soda on the logs close the draft regulators completely to shut off air to the fire Wet down your roof and adjacent areas to keep the fire from spreading 5 If you must use green wood and we urge you to avoid doinf so be sure to mix with dry logs Glass In the event that you need to cle...

Страница 15: ...od Stove notify your nearest dealer or contact Sierra Products Inc at www sierraproductsinc net customer support technical service Sierra Products Inc 63 Laxalt Dr Carson City NV 89706 www sierraproductsinc net P N 140821r2 S8000II WOOD STOVE MANUAL 15 ...

Страница 16: ...service center SPI may require the consumer to supply reasonable proof of the stoves purchase date This warranty is in lieu of any other express warranty Any implied warranties including but not limited to any implied warranty of merchantability or fitness for a particular purpose shall not extend beyond one year from the date of purchase The purchaser s sale and exclusive remedy shall be for the ...