Sierra Flame Lynwood W76 Скачать руководство пользователя страница 28

Page 28

9. SIERRA FLAME Limited Warranty

What’s Covered 

SIERRA FLAME warrants, to the original retail buyer only , that the cast iron and steel components 

of this appliance will be free of defects in material and workmanship for a period of five (5) years 

from the date of purchase.   

 

The enamel finish on the cast iron components is warranted against peeling or fading  for a period 

of two years from the purchase date to the original retail buyer . 

 

The Warranty expires when the original retail buyer transfers ownership.

These  warranties  are subject to the terms, exclusions and limitations set forth below. 

   

What’s not Covered: 

•  Repair or replacement of parts that are subject to normal wear and tear during the warranty 

period or to parts that may require replacement in connection with normal maintenance. These 

parts include paint, gaskets, , vermiculite baffles and panels , and glass 

•  Damage due to incorrect installation that do not comply instructions contained in this owner’s 

manual or local and/or national fire and building regulations.

• 

Damage, including damage to enamel surfaces, caused by improper operation, over firing, and/

or misuse.  Do not burn the appliance with the door open. If any part of the stove or chimney 

connector glows red it is being over-fired.  Warped plates, rust colored cast iron, paint pigment 

that has turned dusty white, or bubbling, cracking and discoloration of the enamel finish are in

-

dications of over-firing. Misuse also includes, any use that does not conform with the operating 

instructions contained in this owner’s manual. 

• 

Damage to enamel finish including chipping, mechanical or chemical abrasion, crazing, or 

staining 

•  Rust caused by high humidity or salt air environments. 

•  Damage from or repair of rust. 

•  Damage due to service performed by an installer or service agency.

• 

Damage caused by unauthorized modification, use or repair. 

•  Costs incurred by travel time and/or loss of service. 

•  Labor or other costs associated with the repair of components beyond the warranty period. 

•  Damage incurred while the appliance is in transit.

•  SIERRA FLAME will not cover labor charges, consequential damages (including, but not limited 

to: the costs of repairing or replacing other property that is damaged when the warranted prod

-

uct fails), or incidental damages (including, but not limited to: the costs a consumer incurs in 

order to obtain warranty service, such as shipping charges, telephone charges, time lost from 

work, transportation costs, and the cost of renting a product temporarily to replace the warrant-

ed product).  Some states do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation or exclusion may not apply to you. 

How to Get Service

SIERRA FLAME will repair or replace, at its option, any of the above components determined by 

SIERRA FLAME to be covered by this warranty. You must, at your own expense, arrange to deliver 

or ship the component to an authorized SIERRA FLAME dealer and arrange for pickup or delivery 

of the component after repairs have been made. 

 

 

 

Содержание Lynwood W76

Страница 1: ...compliant with 2020 cord wood standard This solid fuel heater has been tested and listed according to ULC S627 00 2016 and UL 1482 2011 standards by an accredited laboratory Certified Safety Tests per...

Страница 2: ...er flammable vapors and liquids in the vicinity of this or any other appliance Do not use chemicals or fluids to start the fire Comply with all minimum clearances to combustibles as specified Failure...

Страница 3: ...ng the connector pipe to the stove 13 Combustible Wall Chimney Connector Pass Throughs 14 Chimney height requirements 16 4 Prepare the Stove 17 5 Instructions 20 Fire resistant inner plates 20 Glass 2...

Страница 4: ...Wisconsin to the Environmental Protection Agency 2020 Cord wood standard and is safety listed by PFS to ULC S627 00 2016 and UL 1482 2011 The serial number is fixed to the stove and to the guarantee c...

Страница 5: ...efficiency at a specific burn rate LHV 7 This appliance is officially tested and certified by an independent agency Particulate Emissions rate is obtained using EPA Test Method 8 Carbon Monoxide Emiss...

Страница 6: ...T TOUCH AND KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS USE GLOVES WHEN STOKING THE FIRE 5 DO NOT CONNECT THIS STOVE TO A CHIMNEY FLUE CONNECTED TO ANOTHER STOVE OR APPLIANC...

Страница 7: ...tructed properly to meet all requirements You have all necessary permits from your local authorities Your local building official is the final authority for approving your installation as safe and in...

Страница 8: ...the chimney inspected by a local fire marshal or qualified installer Remember that the chimney and its location on the roof heavily influences the stoves performance An oversized flue may not provide...

Страница 9: ...27 5 699 mm 11 5 292 mm 10 254 mm 6 single wall and optional heat shield 16 406 mm 11 279 mm 16 406 mm 27 5 699 mm 14 356 mm 18 457 mm 6 double wall ventilated and optional heat shield 16 406 mm 5 127...

Страница 10: ...nd proper draft operation Ceiling height clearance Do not install in a room with a ceiling hight below 6 0 182 cm Alcove clearance The minimum alcove width is 63 160 cm The minimum alcove height is 63...

Страница 11: ...ney Connector Pass Throughs on the following pages When connecting the SIERRA FLAME Lynwood to an existing chimney Remove the existing damper and or any portion of the smoke shelf necessary to accommo...

Страница 12: ...Each chimney connector or stove pipe section must be connected to the stove flue collar and to each other with the male crimped end toward the stove Each adjacent piece of connector must be fastened w...

Страница 13: ...or CAN CSA_B365 guidelines and methods Required installation components Chimney cap Insulated chimney Tee section Tee support bracket Chimney connector pipe Wall thimble Wall strap Multi purpose cap S...

Страница 14: ...ngth and wall combustibles Use sheet metal supports fastened securely to wall surfaces on all sides to maintain the 9 228 6 mm air space When fastening supports to chimney length do not penetrate the...

Страница 15: ...Keep solid pak section concentric with and spaced 1 25 4 mm off the chim ney connector by way of sheet metal support plates at both ends of chimney section Cover open ing with and support chimney sec...

Страница 16: ...on and a minimum of 2 feet higher than any roof surface within 10 feet Check with your local building officials for additional requirements for your area The condition of the chimney and height is ver...

Страница 17: ...tallation By removing removable parts it is easier to move the appliance and to avoid damage Note the location of those removable parts so that you have no difficul ties in installing the parts in the...

Страница 18: ...baffle plates should be replaced follow this procedure Disassembly 1 Loosen the nuts 1 2 from the front airtube 3 use penetrating oil 2 Lower front airtube 3 and hold both frontal baffle plates 4 5 wi...

Страница 19: ...Page 19 2 3 1 4 6 8 9 12 11 10 7 5...

Страница 20: ...en the air wash air intake is fully opened When operating the stove on low for extended periods of time the glass may become dirty A short hot fire will help clean off much of the normal soot buildup...

Страница 21: ...n Cut a 4 100 mm hole in outside wall or floor to accommodate outside air piping Use 4 100 mm aluminum metal flex or rigid piping to directly connect outside air to appliance intake Install a terminat...

Страница 22: ...e amounts of fuel to the stove should be avoided it is important to supply it with sufficient fuel to maintain a moderately hot fire this is particularly important since burning wood produces volatile...

Страница 23: ...ppliance Move the control arm to the MAX position Spread out the charcoal bed evenly across the bottom of the fire compartment Stack a few logs on the charcoal bed Close the door of the appliance When...

Страница 24: ...ake sure the fire is out and stove is cold before removing ashes The cast iron inner plates on the bottom of the fire chamber have pockets You should leave ash in the pockets during the heating season...

Страница 25: ...o well cleaned glass Proceed as follows Remove dust and loose soot with a dry cloth Clean the glass with stove window cleaner Apply stove window cleaner to a kitchen sponge rub down the entire glass s...

Страница 26: ...ew posts and reinstall the washers and their gaskets Creosote Formation and the Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with ex pelled moistu...

Страница 27: ...not too many bends no obstructions in chimney bird s nest too much soot deposit hermetically tight no leaks Chimney stack incorrect Sufficiently high above the roof no obstacles in its vicinity Air in...

Страница 28: ...tions of over firing Misuse also includes any use that does not conform with the operating instructions contained in this owner s manual Damage to enamel finish including chipping mechanical or chemic...

Страница 29: ...SIERRA FLAME reserves the right to discontinue modify or change the materials used to produce SIERRA FLAME products SIERRA FLAME shall have the right to replace any defective compo nent with substitut...

Страница 30: ...Page 30 780 mm 30 1 16 153 mm 6 0 16 153mm 6 0 16 570 mm 22 7 16 100 mm 3 15 16 100 mm 3 15 16 230 mm 9 1 16 800 mm 31 1 2 645 mm 25 3 8 205 mm 8 1 16 Dimensioned Drawing...

Страница 31: ...Page 31 Spare Parts...

Отзывы: