Page 13
Rear vent installation
For venting into a masonry or a back standing steel
chimney through the top vent the top horizontal por-
tion of a single wall connector pipe can be located not
closer than 18” below a combustible ceiling.
Rear venting into a masonry or steel chimney through
a thimble vent configuration or other than described
here must follow local codes or NFPA 211 or CAN/
CSA_B365 guidelines and methods.
Required installation components:
Chimney cap
Insulated chimney
Tee section
Tee support bracket
Chimney connector pipe
Wall thimble
Wall strap
Multi-purpose
cap
Storm collar
Flashing
Support bracket assembly
Chimney section
Pipe end plate
T & branch extension
Wall support with clean-out
Wall face
plate
Wall
thimble
Connector
pipe
Mounting the connector pipe to the
stove
Place connector pipe in the flue collar.
Use two self-tapping screws in the holes provided to secure the connector pipe so that it cannot be
lifted of turned from the stove.