background image

STEP 4

Hardwire the 
VersiCharge and 
Ferrite core 
installation - skip if 
using an existing    
240 V outlet.            
(Figure 6)

VersiCharge will need to be mounted on the bracket to hardwire the device.

Plug-supplied units only:

1.  Open the VersiCharge to expose backside of the unit.

2.  Remove the high voltage door by releasing snaps (Use flat head screwdriver if needed to assist).

3.  Disconnect the attachment plug wires from the terminal block by loosening screws in positions 1, 2, and 3 and remove the  
  Ferrite core (the core will be reinstalled when hardwired).

4.  Disconnect and remove strain relief and entire cord-and-plug assembly and follow Hardwiring for plug and non-plug units  
 below.

Hardwiring for plug and non-plug units:

NOTE:

 Do not adjust the two screws on the right side of the terminal block relays. These are for factory use only.

1.  Expose the wiring terminals by opening the back of the unit, loosen lug screws. 

2.  Route conductors into the VersiCharge from the conductor opening with proper strain relief.

3.  Pull 3-6 inches of slack through the conductor opening.

4.  Locate the Ferrite core (the Ferrite core supplied in the resealable plastic bag or reserved when the plug was removed). Slide  
  the Ferrite core over the black and red wires ONLY, and into position per Figure 6 (the green wire/ground should not be  
  placed through the Ferrite core).

5.  Wire conductors (copper only) into VersiCharge (L1, L2 and Ground) from connected conduit. Using torque screwdriver,  
  torque all lugs to 14.5 lb.-in. See Appendix D for wire bending diagram.

6.  Replace the high voltage door and secure by engaging snaps.

7.  Swing the unit closed until the bracket clip engages and secure the charger with the tamper-resistant security screws.

8.  Turn the circuit breaker for this circuit to the ‘ON’ position.

NOTE: 

1.  When installing the hardwired VersiCharge, power connections shall be made at line terminals with 14.5 in-lb. torque driver. 

2.  The rating of the circuit breaker that will be required is based on the ampere rating of the EVSE; 40A requires 50A breaker,  
  48A requires 60A breaker. Verify that the amp adjustment switch is set per the table above.

3.  Plug removal is only necessary when hardwiring a plug-supplied VersiCharge unit. 

NOTE:

 This enclosure has not been evaluated for rigid metallic and rigid non-metallic conduit. In order to maintain a                            

Type 4 UL50E environmental rating, a hardwired installation should use liquid tight flexible conduit only, with conduit glands 
rated UL Type 4, 4X, 6 or 6P.

STEP 5

SIM Card Installation 
- Commercial Parent 
Units Only (Figure 7)

If not factory installed, SIM Card Installation Information

This hardware uses a micro SIM card, but with an adapter will allow nano SIM cards. 

The SIM card should NOT require a PIN. Locked SIM cards are not supported by VersiCharge hardware. 

The following carriers are supported : USA-AT&T, T-Mobile and Canada-Rogers/Telus. Data plans should have a minimum 
consumption of 250 MB per month per charger

Expose the area holding the SIM card hardware by unlatching the cover. The SIM card sits next to the Ethernet connection 
(see STEP 9). Slide the micro SIM card into slot. (SIM card to be supplied by the service provider). 

The SIM card socket is spring loaded. Slide the SIM card from the bottom upward into the slot until it stays in place. 

To remove/replace the SIM card, press the SIM card upward and it will “spring” down and out of the slot.

STEP 6

Connect Ethernet  
- Residential and 
Commercial Units 
(Figure 8)

NOTE:

 The Ethernet cable connector should NOT be on the Ethernet cable when it is pushed through the rubberized gland.  

This gland will not self-seal if the connector is pushed through the rubberized gland and the NEMA 4 rating will be lost.

Push the Ethernet cable through the rubberized gland and snake it up through the back to the opening. Connect the 
Ethernet RJ45 plug to the cable. Insert the RJ45 plug from the bottom up into the Ethernet port.

11

VersiCharge™ AC Electric vehicle charging station

Содержание VersiCharge AC

Страница 1: ...QUICK START INSTALLATION GUIDE VersiCharge AC Electric vehicle charging station ...

Страница 2: ... 10 Maintenance 14 General exterior maintenance 14 General external checks 14 APPENDIX A Human Machine Interface HMI 15 APPENDIX B System Operation Faults 16 APPENDIX C Useful Links 20 APPENDIX D Hardwire Bending Diagram Dedicated 21 3 VersiCharge AC Electric vehicle charging station ...

Страница 3: ...ure 7 SIM Card Installation 8 Figure 8 CAT6 Ethernet Port Connection 8 Figure 9 Serial RS485 ModBus Connection 8 Figure 10 Commercial ModBus Termination Switch 8 Figure 11 ModBus Termination Switch 8 Figure 12 External Remote Control Interface 8 Figure 13 Close Charger 9 Figure 14 Secure Charger 9 Figure 15 Holster Installation 9 Figure 16 Residential HMI 15 Figure 17 Commercial HMI 15 4 VersiChar...

Страница 4: ...If using the Alternate Installation a Phillips Head Screwdriver will also be needed 6AWG90 Ccopperwireshouldbeused for 48A chargerand 8AWG90 Ccopper wire shouldbeusedfora40Acharger NOTE 1 Wiremusthaveatemperature rating of90 Corhigher 2 Donotsetthe ampswitchhigherthan40Aunlesshard wiredto adedicated60Abranchprotection circuit breaker 40A charger requires a 2 pole 240V 50A circuit breaker 48A charg...

Страница 5: ...ton Head Cap Screws secure the charger 2 3 Alternate Installation Wallboard Installation What you will need screws and anchors are not included in the VersiCharge installation kit 5 12 x 1 LG Phillips head Ø 375 head minimum with 5 12 wall anchors NOTE wall anchors must be rated for 61 lbs for 1 2 dry wall Admin Card Admin Card User Card User Card User Card User Card User Card NOTE Supplied with C...

Страница 6: ...tial See page 10 Charger Mounting STEP 2 STEP 3 STEP 4 Figure 4 Hanging Charger Figure 5 Set Amp Switch Figure 6 Charger Hardwiring and Ferrite Core Commercial Residential See page 10 Commercial Residential See page 10 Installation Commercial Residential See page 11 See Appendix D for wire bending diagram P1 Black Hot Power P2 Green Ground Earth P 3 Red Hot Power Ferrite Core 7 VersiCharge AC Elec...

Страница 7: ...ommercial Parent ModBus Termination Switch Setting Commercial Only See page 12 Steps 5 through 9 are only applicable to specific models features Match the charger feature to the installation step Steps 10 through 12 are applicable to ALL chargers Figure 11 Commercial Child ModBus Termination Switch Setting Commercial Only See page 12 Figure 12 External Remote Control Interface Commercial Only See ...

Страница 8: ...e 15 Holster Installation Commercial Residential See page 13 Figure 13 Close Charger Commercial Residential See page 13 Figure 14 Secure Charger Commercial Residential See page 13 9 VersiCharge AC Electric vehicle charging station ...

Страница 9: ...mounting to the wall securely 5 Add a 5th hole for mounting the holster once the unit is mounted on the wall Place the holster on the wall and mark the correct position for the hole Refer to Step 12 STEP 2 Install Mount Charger Figure 4 NOTE For installation the mounting bracket hinges will be pointing to the ceiling and the flat side of the bracket will be against the wall 1 Slide the VersiCharge...

Страница 10: ...ith 14 5 in lb torque driver 2 The rating of the circuit breaker that will be required is based on the ampere rating of the EVSE 40A requires 50A breaker 48A requires 60A breaker Verify that the amp adjustment switch is set per the table above 3 Plug removal is only necessary when hardwiring a plug supplied VersiCharge unit NOTE This enclosure has not been evaluated for rigid metallic and rigid no...

Страница 11: ...sponsibility of the installer to ensure the security of the wiring of these connections to prevent tampering STEP 8A Set ModBus Parent Termination Switch Commercial Units Only Figure 10 SW3 1 left side labelled RS485 is the Termination switch This switch should be in the ON position for the Parent unit or in the OFF position for a Child unit unless that Child is the last Child in the daisy chain t...

Страница 12: ...igure 15 1 Secure charger Figure 14 Using the kit supplied tamper resistant screw secure the charger cover with one screw on the side 2 Install holster to charger Align Holster with guides in charger Using the kit supplied tamper resistant screw use the third screw to secure the holster to the charger hole at the top of the holster 3 Standard installation using the kit supplied lag screw screw int...

Страница 13: ...r for harder to removed marks use an alcohol based cleaner Do not spray with high pressure cleaning hoses or use abrasive chemicals General external checks Check for cuts cracks damage and debris If debris is present remove it If you find damage contact your supplier Check for damage and corrosion If present contact your supplier Check the HMI for damage signs of faded color that is clearly visibl...

Страница 14: ...D Power On 2 Status LED Car Connected Cold Start 3 Status LED Charging 4 Status LED Fault 5 Wi FI LED 6 Blue Tooth LED 7 Time Delay LED 2 Hr 8 Time Delay LED 4 Hr 9 Time Delay LED 6 Hr 10 Time Delay LED 8 Hr 11 Charging Process Light 12 Touch Sensitive Button 13 Unit Under Remote Control 14 Front Panel Locked 15 Fault Conditions Audible HMI Elements 16 RFID Accept Decline 17 Relays Switching Sound...

Страница 15: ...ID card over the RFID reader NOTE The charger is in the unlocked state by default Lights up white Charging station is ready LED off Charging Paused Charging can be resumed through the Mobile App Lights up white Vehicle connected Lights up white Charging in progress Flashes white After switch on the charger will go to Access Point mode Connect PC or mobile device for commissioning charger is ready ...

Страница 16: ...le App Flashes white 2 h delay Wait until charging process starts Flashes white 4 h delay Wait until charging process starts Flashes white 6 h delay Wait until charging process starts Flashes white 8 h delay Wait until charging process starts Press Touch Sensitive Button to add a time delay Press the Touch Sensitive button once for 2 hour delay twice for 4 hour delay three times for 6 hour delay a...

Страница 17: ... and hold for 5 seconds to reset Flashes red A fault has occurred Turn the supply voltage off and on again A fault has occurred Error code 001 Notify Technical Support Lights up red A fault has occurred Error code 002 Notify Technical Support Lights up red A fault has occurred Error code 003 Notify Technical Support Lights up red A fault has occurred Error code 004 Notify Technical Support Lights ...

Страница 18: ... has occurred Error code 008 Notify Technical Support Lights up red A fault has occurred Error code 009 Notify Technical Support Lights up red A fault has occurred Error code 0010 Notify Technical Support Cold Start Lights up steady white Random delay between 1 5 minutes on power cycle if EV is connected EVSE will resume charging after delay expires No Action 19 VersiCharge AC Electric vehicle cha...

Страница 19: ...om us app versicharge id989742892 Download the VersiCharge Configuration Tool PC application Recommended for Commercial installations https assets new siemens com siemens assets api uuid e2ab1265 3049 455f bfc0 1a666b4b76f1 versichargeconfiguratorsetup1 1 2 zip Find the following at usa siemens com versicharge Configure your VersiCharge VersiCharge Frequently Asked Questions Detailed VersiCharge I...

Страница 20: ... NOTE The rating of the circuit breaker that will be required is based on the ampere rating of the EVSE 40A requires 50A breaker 48A requires 60A breaker Also the wiring should not be exposed to weather water or conditions that could potentially damage wiring or cause a short 21 VersiCharge AC Electric vehicle charging station ...

Страница 21: ...Notes 22 VersiCharge AC Electric vehicle charging station ...

Страница 22: ...Notes 23 VersiCharge AC Electric vehicle charging station ...

Страница 23: ...Notes 24 VersiCharge AC Electric vehicle charging station ...

Страница 24: ...S T40066 00 4AUS This document contains a general description of available technical options only and its effectiveness will be subject to specific variables including field conditions and project parameters Siemens does not make representations warranties or assurances as to the accuracy or completeness of the content contained herein Siemens reserves the right to modify the technology and produc...

Отзывы: