TC63 AT Command Set
2. Configuration Commands
s
TC63_ATC_V00.490
Page 30 of 501
5/24/05
Confidential / Draft - Do not copy
2.
Configuration Commands
The AT Commands described in this chapter allow the external application to determine the TC63's behaviour
under various conditions.
2.1
AT&F Set all current parameters to manufacturer defaults
AT&F
sets all current parameters to the manufacturer defined profile. All defined GPRS contexts which are not
activated or not online will be undefined (see
AT+CGDCONT
).
Syntax
Parameter Description
[0]
Set all TA parameters to manufacturer defaults
Notes
• List of parameters reset to manufacturer default can be found in Section
21.6
,
Factory Default Set-
tings Restorable with AT&F
.
• In addition to the default profile, you can store an individual one with
AT&W
. To alternate between the two pro-
files enter either
ATZ
(loads user profile) or
AT&F
(restores factory profile).
• Every ongoing or incoming call will be terminated.
Exec Command
AT&F
[
<value>
]
Response(s)
OK
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
V.250
!
%
%
%
%
%
%
!
%
!
<value>
(num)