RN-S SA
Operating Instructions, 09/2016, A5E32605810A-03
27
Mounting
5
5.1
Safety information/instructions
Load cells are precision components and must therefore be handled carefully. Particular
care must be taken during transport and installation.
DANGER
Danger to life from falling loads
•
Load cells are not machine components which have been constructed with the normal
safety factors. For this reason, appropriate protection against falling and catastrophes
must be implemented in accordance with the potential risks.
•
Use suitable hoisting equipment to lift the load carrier. Observe the appropriate safety
regulations.
NOTICE
Damage to load cells through incorrect handling
•
SIWAREX load cells are only permitted to be mounted and connected by qualified
personnel.
•
Mechanical shocks or falls can irreparably damage the load cell.
•
When mounting the load cell, ensure that you do not damage or cut the cables of the
load cell. Load cells must not be carried by their connecting cables.
•
Protect the load cells from shocks and welding currents. Replace the load cells with
dummies until the installation work on the scale structure is completed.
NOTICE
Damage to load cells through high currents
•
If welding is undertaken after the load cells have been installed, ensure that the welding
current is not diverted through the load cells.
–
You can do this by attaching the grounding clamp of the welding unit making reliable
contact close to the weld.
–
Bridge the load cells with a ground cable, see Use of the grounding cable (Page 13)
–
Disconnect the individual load cells.
•
Undesirable electrical currents can arise during lightning. To protect the load cell against
such currents, bridge the load cells using highly flexible grounding cables, see also Use
of the grounding cable (Page 13).
Содержание SIWAREX WL280
Страница 8: ...Introduction 1 5 Environmental protection RN S SA 8 Operating Instructions 09 2016 A5E32605810A 03 ...
Страница 20: ...Description 3 2 Design and function RN S SA 20 Operating Instructions 09 2016 A5E32605810A 03 ...
Страница 44: ...Mounting 5 4 Dismantling RN S SA 44 Operating Instructions 09 2016 A5E32605810A 03 ...
Страница 48: ...Technical data 7 2 Stainless steel guide elements RN S SA 48 Operating Instructions 09 2016 A5E32605810A 03 ...
Страница 56: ...Appendix A 1 Technical support RN S SA 56 Operating Instructions 09 2016 A5E32605810A 03 ...