SITRANS RD300
A5E31917845
SITRANS RD300 – OPERATING INSTRUCTIONS
Page 19
Display
Parameter
Action/Setting Description
conversion
factor
T rst
Total reset
Program total rest mode: auto or manual
GT tb
Grand total
time base
Program grand total time base
GT CF
Grand total
conversion
factor
Program grand total conversion factor
GT rst
Grand total
reset
Program grand total rest mode: auto or
manual
Auto
Automatic
Press Enter to set automatic total reset
T dly
Time delay
Program time delay for total auto reset
mAn
Manual
Press Enter to reset total manually
dsplay
Display
Enter the
Display
menu
Line 1
Display line 1
Press Enter to assign the upper display
parameter (default: PV or rate)
Line 2
Display line 2
Press Enter to assign the lower display
parameter (default: total)
d-Inty
Display
intensity
Set display intensity level from 1 to 8
RELaY
Relay
Enter the
Relay
menu
Assign
Assignment
Assign relays to rate, total, or grand total
Asign1
Assign 1
Relay 1 assignment
totAL
Total
Assign relay to total
G total
Grand total
Assign relay to grand total
m bus
Modbus
Select to display Modbus input or to assign
Modbus input as the analog output source
rate
Rate
Assign relay to rate
RLY 1
Relay 1
Relay 1 setup
Act 1
Action 1
Set relay 1 action
Auto
Automatic
Set relay for automatic reset
A-nman
Auto-manual
Set relay for automatic & manual reset
any time
LatCH
Latching
Set relay for latching operation (relays
assigned to rate)