7ML19985FT62
SITRANS LVS200 – INSTRUCTION MANUAL
Page EN-5
m
mmmm
Englis
h
• mA output (build-up detection)
8/16 mA or 4 to 20 mA;
resolution 4 to 20 mA, ±0.1 mA
Mechanical
Process Connection
• thread
1½” NPT, 1½” BSPT
• flanges
DN 100 PN6, DN 100 PN16,
2", 3", 4" ASME 150 lb flanges
• optional sliding bushing
with 2" NPT or BSP thread
• thread material
stainless steel 303 (1.4301) or
optional stainless steel 316 Ti (1.4571)
Tines
• tine material
stainless steel 316Ti (1.4571)
(PTFE
1
coated tines are available upon special request. Contact your local Siemens
Milltronics representative for ordering information.)
Enclosure
• construction
epoxy-coated aluminum
• conduit entry
2 x M20x1.5, or 2 x ½” NPT
• ingress protection
Type 4X/NEMA 4X/IP66
Weight
• standard version, no extensions
2.0 kg (4.4 lb)
• solids/liquids, no extensions
1.9 kg (4.2 lb)
Environmental
• location
indoor/outdoor
• altitude
max. 2000 m (6562 ft)
• ambient temperature
–40 to 60 °C (–40 to 140 °F)
• relative humidity
0 to 100% (suitable for outdoor: ingress
protection: Type 4X/NEMA 4X/IP66)
• installation category
III
• pollution degree
2
Process
Temperature
• All approvals except CSA Class II, Group G: –40 to 150 °C (–40 to 302 °F)
• CSA Class II, Group G:
–40 to 140 °C (–40 to 284 °F), CSA
temperature code T3B
• For applications with process temperature greater than 80 °C (176 °F), the
maximum threaded bushing surface temperature must not exceed 80 °C (176 °F)
1.
Polytetrafluoroethylene