Page EN-8
SITRANS LVS200 – INSTRUCTION MANUAL
7ML19985FT62
mmmmm
English
SITRANS LVS200 is normally mounted into the vessel top for full detection, or through the
tank wall at the detection level, for full, demand, or empty detection.
Process Cautions
Cable gland faces
downward to avoid
water penetration.
Protection in case of
high material loading.
Use angle mounting for flowing
material only.
If angle mounting is required
with high material loading,
customer-supplied protection
from falling material must be in
place.
*
max. deviation
from vertical
α
max. length L
5º
4 m
45º
1.2 m
>45º
0.6 m
*
L
Tine orientation
marking facing
sideways.
α
Position tines vertically
to avoid product build-
up: use a 50 mm open-
end wrench to turn the
process connection
until the tine
orientation marking
faces up or down.
Sliding
bushing
version
Standard
version
Cable
extension
version
Caution:
•
Locate SITRANS LVS200 out of path of falling material.
or:
•
Protect shaft and tines from falling material.