Installing/Mounting
4.3 MAG 5000/6000 compact
23
8.
Mount connection plate in terminal box.
Note
Check that your connection board lines up with SENSORPROM
®
unit, if not, move
SENSORPROM
®
unit to the other side of terminal box.
SENSORPROM
®
memory unit connections will be established automatically when
connection plate is mounted in terminal box.
9.
Tighten cable glands to obtain optimum sealing.
10.
Mount transmitter on terminal box.
11.
Transmitter is ready to be powered up.
NOTICE
Exposing transmitter to direct sunlight may increase operating temperature above its
specified limit, and decrease display visibility.
A sunshield is available as accessory.