01.99
8 Diagnosis
© Siemens AG 1999 All Rights Reserved
6FC5198-6AA60-0BP1
SINUMERIK 840C, OEM Version for Windows (BA)
8-11
8.2.4
On-line help for alarms and messages
The user can call up additional information on alarms by positioning the
selection bar on the alarm with the ARROW keys and pressing the HELP key:
Fig. 8-5
On-line help for alarms
The on-line help for alarms is presented in a standard format. The header of
each alarm description provides information on the alarm number, the alarm
text and the clearance mode.
Table 8-3
Overview - On-line help
Alarm number
Alarm text
Clear key
Query:
Details of the state in which the alarm occurred.
Effect:
Details of the effect of triggering the alarm.
Explanation:
Details of the reasons for the occurrence of the alarm.
Remedy:
Instructions for eliminating the alarm state.
The help menu can be closed again by selecting the Exit command in the File
menu.
The Contents, Search, Back, History and Browse ( << and >> ) commands
in the toolbar shown above can be selected using the appropriate HOTKEYS
on the operator panel.