4 Monitoring Functions
09.91
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
3012
”Block not in memory”
Reason:
Remedy:
– The program has not been terminated with M02/M30/M17
– In a jump instruction (@ 100, 11y, 12y, 13y) the given block number
was not found in the given direction
– A @ instruction was programmed in the function “block transfer”.
As for alarm 3000
Alarm No.
Alarm Text:
3013
”Simulation disabled”
Reason:
Remedy:
When the appropriate machine data is set, graphic simulation (for
testing part programs) is only possible when a program is not being
simultaneously run on the machine.
Alarm-No.
Alarm Text:
3016
”External data input error”
Reason:
Effect:
Remedy:
During external data input from PLC to NC:
– the code is incorrect
– the value is too large
– the dimension identifier is invalid
– the option is not fitted
Data transfer is interrupted
– Check PLC program or call Service
Alarm-No.
Alarm Text:
3017
”Part prog. no. occurs twice”
Reason:
Effect:
Remedy:
There is a program present on the cycles EPROM submodule, which
is also present in the part program (RAM) memory.
Inhibiting of NC START
Delete the program in RAM
Alarm-No.
Alarm Text:
3018
”Distance from contour too great (NC MD9)”
Reason:
Effect:
Remedy:
After repositioning to a circular contour, the distance between the axes
and the contour is too great.
The NC inhibits ”Program start”.
Retraverse to the contour to reduce the distance.
Alarm-No.
Alarm Text:
3019
”Option RS232C (V.24) not available”
Reason:
Remedy:
The 2nd RS232C (V.24) interface has been started, either from the
PLC or with the softkey, but the option is not fitted.
– Transfer data via the 1st RS232C (V.24) interface.
– Retrofit option C62 (2nd RS232C (V.24) interface)
4-28
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)
Содержание Sinumerik 810T
Страница 3: ...SINUMERIK810T Basic Version 3 Software Version 3 Part 1 Operating User Documentation ...
Страница 70: ...01 93 2 Operation 2 4 2 JOG mode Siemens AG 1990 All Rights Reserved 6ZB5 410 0EP02 2 49 SINUMERIK 810T GA3 BN ...
Страница 232: ...09 91 3 Operating Sequences 3 2 10 DRF Siemens AG 1990 All Rights Reserved 6ZB5 410 0EP02 3 125 SINUMERIK 810T GA3 BN ...