4 Monitoring Functions
01.93
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
184
*
”Stop behind ref. point”
Reason:
Effect:
Remedy:
When traversing to reference point, the axis was stopped between the
reference cam and the zero mark of the measuring system
– Inhibiting of NC START
– Reference point not reached
Approach reference point again
Alarm No.
Alarm Text:
196
*
”Follow-up /park for axis”
Reason:
Remedy:
Spindle is not active as rotary axis.
Switch spindle to axis mode.
Alarm No.
Alarm Text:
2000
”Emergency Stop”
Reason:
Effect:
Remedy:
The EMERGENCY STOP signal is output from the PLC to the NC
– Inhibiting of NC START
– Operation is brought to a defined stop
– Servo enable is removed
– Follow up operation
Check to see if the EMERGENCY STOP cam was traversed to, or if
the EMERGENCY STOP switch was operated
Alarm No.
Alarm Text:
2030
”Wrong path increment”
Effect:
Remedy:
Explanation:
–
Locking of NC START
–
Locking of NC Ready
–
Machining stop
Check G06 block, recalculate and correct if necessary.
Distance-to-go contains an incorrect value which does not match the
programmed contour
_______
”*” stands for : ”0” = axis 1, ”1” = axis 2, ”2” = axis 3, ”3” = axis 4, ”4” = axis 5
4-14
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)
Содержание Sinumerik 810T
Страница 3: ...SINUMERIK810T Basic Version 3 Software Version 3 Part 1 Operating User Documentation ...
Страница 70: ...01 93 2 Operation 2 4 2 JOG mode Siemens AG 1990 All Rights Reserved 6ZB5 410 0EP02 2 49 SINUMERIK 810T GA3 BN ...