p30455
RAILCTRL encoder linearization / Encoder linear
All objects
Can be changed: T
Calculated: -
Access level: 3
Data type: Unsigned8
Dynamic index: -
Function diagram: -
P-Group: -
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
0
Max:
127
Factory setting:
0
Description:
Sets the linearization for the Festo SDAT encoder.
If a non-supported linearization is set, the encoder automatically uses the standard linearization.
p30460
RAILCTRL start of measuring range / Meas range start
All objects
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7361
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
0.00 [mm]
Max:
340.28235E36 [mm]
Factory setting:
40.00 [mm]
Description:
Sets the local (referred to the segment) coordinate for the start of the measuring range of the selected encoder.
The measuring range length is set using p30462.
Dependency:
See also: p30453, p30462
Note
The position outside the measuring range is set to zero.
p30461
RAILCTRL start of the primary section / Primary sect start
All objects
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7361, 7363
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
0.00 [mm]
Max:
340.28235E36 [mm]
Factory setting:
50.00 [mm]
Description:
Sets the local (referred to the segment) coordinate for the start of the primary section.
The primary section length is set using p30463.
Dependency:
Only active in the closed-loop controlled mode.
See also: p30463
p30462
RAILCTRL measuring range length / Meas range length
All objects
Can be changed: C1(3)
Calculated: -
Access level: 3
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 7361
P-Group: Closed-loop control
Unit group: -
Unit selection: -
Not for motor type: -
Scaling: -
Expert list: 1
Min:
0.01 [mm]
Max:
340.28235E36 [mm]
Factory setting:
326.00 [mm]
Description:
Sets the length of the measuring range of the selected encoder.
The start of the measuring range is set using p30460.
Dependency:
See also: p30453, p30460
Note
The position outside the measuring range is set to zero.
Parameter
RAILCTRL
Function Manual, 09/2019, A5E38120767B
59
Содержание SINAMICS RAILCTRL
Страница 1: ...Function Manual Rail Control RAILCTRL Edition SINAMICS 09 2019 www siemens com drives ...
Страница 2: ......
Страница 14: ...Safety instructions 2 3 Industrial Security RAILCTRL 12 Function Manual 09 2019 A5E38120767B ...
Страница 18: ...Applications and characteristics 3 2 Features RAILCTRL 16 Function Manual 09 2019 A5E38120767B ...
Страница 104: ...Index RAILCTRL 102 Function Manual 09 2019 A5E38120767B ...
Страница 105: ......