Remedy:
In general:
Check the grid spacing/scaling (p0407) or the fine resolution (p0418) of the encoder.
For fault cause = 1:
Check the setting for the start of the primary section (p30461).
For fault cause = 2:
Check the setting for the length of the primary section (p30463).
For fault cause = 3:
Check the setting for the length of the secondary section (p30464).
For fault cause = 4:
Check the setting for the position offset of the secondary section (p30465).
For fault cause = 5:
Check the setting for the hysteresis (p30466).
For fault cause = 6:
Check the setting for the offset of the master/slave transition (p30467).
For fault cause = 7:
Check the setting for the start/length of the primary section (p30461, p30463).
For fault cause = 8:
Check the adjustable parameters for converting the start of the primary section into its own coordinates (p30461, p30465,
p30466, p30467).
For fault cause = 9:
Check the adjustable parameters for converting the end of the primary section into its own coordinates (p30461, p30463,
p30465, p30466).
For fault cause = 10:
Check the adjustable parameters for converting the geometry of the previous segment into its own coordinate system
(p30461, p30463). Where necessary, also check the own parameters for the beginning of the primary section (p30461).
For fault cause = 11:
Check the adjustable parameters for converting the geometry of the subsequent segment into its own coordinate system
(p30461, p30463). Where necessary, also check the own parameters for the start/length of the primary section (p30461,
p30463).
For fault cause = 12:
See the remedy for fault cause 10.
If necessary, also check the own parameters for the length of the secondary section (p30464).
For fault cause = 13:
See the remedy for fault cause 11.
If necessary, also check the own parameters for the length of the secondary section (p30464).
Note:
RAILCTRL: Controller for Segmented Linear Drives
See also: p30461 (RAILCTRL start of the primary section), p30463 (RAILCTRL primary section length), p30464
(RAILCTRL secondary section length), p30465 (RAILCTRL secondary section position offset), p30466 (RAILCTRL
hysteresis), p30467 (RAILCTRL offset master/slave transition)
A53180
RAILCTRL control word invalid
Drive object:
All objects
Message class:
Application/technological function faulted (17)
Message value:
Fault cause: %1
Reaction:
NONE
Acknowledge:
NONE
Faults and alarms
RAILCTRL
Function Manual, 09/2019, A5E38120767B
85
Содержание SINAMICS RAILCTRL
Страница 1: ...Function Manual Rail Control RAILCTRL Edition SINAMICS 09 2019 www siemens com drives ...
Страница 2: ......
Страница 14: ...Safety instructions 2 3 Industrial Security RAILCTRL 12 Function Manual 09 2019 A5E38120767B ...
Страница 18: ...Applications and characteristics 3 2 Features RAILCTRL 16 Function Manual 09 2019 A5E38120767B ...
Страница 104: ...Index RAILCTRL 102 Function Manual 09 2019 A5E38120767B ...
Страница 105: ......