55
Example of a motor power plate / rating plate:
Rated motor voltage: 420 V, rated motor current 985 A
Rated motor speed: 1410 RPM, maximum field weakening speed: 1620 RPM
Field data: 310 V / 14.5 A at speed zero to rated speed 1410 RPM,
at a maximum field weakening speed of 1620 RPM: 210 V / 11.5 A
Field resistance when winding is warm: 310 V / 14.5 A = 21.4
And 210 V / 11.5 A = 18.3
Note:
The field resistance for a warm winding is approx. 25% higher than in the cold state,
the controlled field device in the SINAMICS DCM compensates for this effect with constant
current regulation. The lower resistance at 11.5 A results because the field winding does not
heat up so much with a low field current.
The gearing
Gears are used to adapt the speed of the motor to a particular system speed.
Relationships:
Motor speed / load speed = gear ratio i
Convert load variables to the motor side:
M
L
/ i = M
LM
,
M
L
: Torque on the load side, M
LM
: Load-side torque converted to the motor side.
J
L
/ i
2
= J
LM
J
L
: Moment of inertia on the load side, J
LM
: Load-side inertia converted to motor side.
P
L
= P
M
, the power on the load side corresponds to the power on the motor side.
SIEMENS
DC - Motor
Wärmekl./Th.Cl. H
No. N R7 1145783 010 001 / 2004
V
20 ... 420
420
1GG6286-0NG40-1VV1-Z
EN 60034
IP23 / IC 06
IM B3
A
985
990
1/min
10 ... 1410
1410 ... 1620
kW
2,76 ... 390
390
Fremderr./Separate excit.: 310 ... 210 V, 14,5 ... 11,5 A
Gew./Wt. 1,56 t
Fremdkühlung/Separate cooling: 0,75 m
3
/s
Luftrichtung/
Dir. of Ventilation
NDE-DE
MADE IN GERMANY
B6C, 400 V, 50 Hz
Order No.: MLFB
Serial number/
Factory serial
Armature control
Field control range
Construction
Exciter data
Power