![Siemens SIMOVERT MASTERDRIVE Series Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/siemens/simovert-masterdrive-series/simovert-masterdrive-series_operating-instructions-manual_378159025.webp)
SIMOLINK Pulse Generator
02.2001
Start-Up
Siemens AG
GWE-477 764 4070.76 J
SIMOVERT MASTERDRIVES
Operating Instructions
6-5
Reference speed
[rev/min]
No. of encoder
pulses per rev.
Multiplier
[%]
500
1024
8.53
1000
2000
66.66
1500
2048
51.200
2000
5000
166.667
1)
2500
2000
83.333
3000
2000
100.000
1)
The speed range of the SLP cannot be output with this combination
Table 6-5
Examples for 100 kHz signal mode
KK0414
Calculated multiplier in %
U014.F (0.000 %)
U951.31 =
04
(20)
KK0470
K 571
U110 (0)
.01
y
K 414
.02
x1 x2
100 %
⋅
x1
x2
KK0571
Speed setpoint for
virtual master axis from
ramp-function generator
P751.1
(0)
KK470
SLB transmit data
P751.2
(0)
KK470
U961.31 =
X+n
U961.51 =
X
U951.51 =
04
(20)
Fig. 6-4
Example of setpoint normalization parameter settings
The processing time slot and sequence must be taken into account in
the parameter settings. If a time slot other than the time slot for setpoint
calculation is used or the processing sequence altered, the resulting
dead times will cause a lag in the signal output when the setpoint is
changed.
Parameterization
example
NOTICE