SIMOLINK Pulse Generator
02.2001
Connections
Siemens AG
GWE-477 764 4070.76 J
SIMOVERT MASTERDRIVES
Operating Instructions
5-1
5 Connections
The SIMOLINK Pulse Generator module has the following connectors
♦
X1 for power supply,
♦
X2 for signal output and
♦
a SIMOLINK fiber-optic cable connection with one transmit socket
and one receive socket.
5.1 Connector
X1
The 6-pin connector is on top of the housing. The 24 V power supply to
the SIMOLINK Pulse Generator is connected via X1.
M
+24 V
Connector
Socket X1
Fig. 5-1
Terminal
Designation
Meaning
Range
1
-
Unused
2
-
Unused
3
-
Unused
4
-
Unused
5
M
Ground
6
+24V
24 V power supply
+21 ... 28 V
Connectable cross-section: 1.5 mm
2
(AWG 16)
Terminal 1 is the terminal to the rear of the module top plate (see plan view).
Table 5-1
Connector assignments