Data
SIMOTION CX32
● With lamp load
11 Hz
Short-circuit protection
Yes
1)
Data for: Vcc = 24 V; load 48 Ohm; H = 90% V
out
, L = 10% V
out
2)
The digital inputs are protected against polarity reversal up to -30 V
7.5
CBE30 communication board Ethernet
7.5.1
CBE30 communication board
Characteristics of the CBE30
The CBE30 Ethernet communication board for SIMOTION D4x5 enables connection to a
PROFINET IO network. The SIMOTION D4x5 then assumes the role of a PROFINET IO
Controller and can offer the following functions:
● PROFINET IO controller, I device (also controller and device simultaneously)
● 100 Mbit/s full duplex/autocrossing
● Supports real-time classes of PROFINET IO:
– RT (real-time)
– IRT (isochronous real-time)
The CBE30 has an X1400 interface with an integral 4-port switch based on PROFINET ASICs
ERTEC400.
NOTICE
Damage to the CBE30 caused by electric fields or electrostatic discharge
Option boards are ESD-sensitive components.
De-energize the SIMOTION D4x5 device before inserting or removing the option board.
SIMOTION D4x5 is in a de-energized state when all the LEDs are OFF.
Comply with the ESD rules.
Supplementary system components
7.5 CBE30 communication board Ethernet
SIMOTION D4x5
Manual, 04/2014
107