Motor components and options
4.1 Motor components
1FW68 radial segment motors
Configuration Manual, 04/2017, 6SN1197-0AE02-0BP1
69
No direct connection of the temperature monitoring circuits
WARNING
Risk of electric shock when incorrectly connecting the temperature monitoring circuit
In the case of a fault, circuits Temp-S and Temp-F do not provide safe electrical separation
with respect to the power components.
•
Use the TM120 to connect the Temp-S and Temp-F temperature monitoring circuits.
You therefore comply with the directives for safe electrical separation according to
DIN EN 61800-5-1 (previously safe electrical separation according to DIN EN 50178).
Correctly connecting temperature sensors
NOTICE
Motor destroyed as a result of overtemperature
The motor can be destroyed as a result of overtemperature if you do not correctly connect
the temperature sensors.
•
When connecting temperature sensor cables with open conductor ends, adhere to the
correct assignment of conductor colors as described in "Signal connection (Page 147)".