Electrical connection
8.3 System integration
1FW68 radial segment motors
158
Configuration Manual, 04/2017, 6SN1197-0AE02-0BP1
Figure 8-11 Leading EMF phase U stator segment 1
Checking the phase voltage and pole position angle using an oscilloscope
1.
Carefully observe the fundamental safety instructions and safety instructions relating to
electrical connection.
2.
Switch the drive line-up into a no-current condition.
3.
After the DC link has been fully discharged, disconnect the motor cables from the Motor
Module.
Disconnect the parallel circuit connections between the stator segments.
4.
Using 1 k
Ω
resistors, create an artificial neutral point for each stator segment.
①
Stator segment
②
1 k
Ω
resistor
Figure 8-12 Arrangement for measuring