Electrical connection
8.3 System integration
1FW68 radial segment motors
Configuration Manual, 04/2017, 6SN1197-0AE02-0BP1
153
Components
●
1 CU 320-2 Control Unit
●
1 Active Interface Module AIM to dampen line oscillations
●
1 Active Line Module ALM as infeed and rectifier
●
5 Motor Modules as inverters
●
9 circuit breakers
●
9 stator segments subdivided into 5 groups
–
Group 1 (master drive):
2 stator segments connected in parallel to one Motor Module; encoder evaluation only
via group 1
–
Group 2 to group 4 (slave drives):
2 stator segments connected in parallel to one Motor Module, groups are identically
configured
–
Group 5 (slave drive):
1 stator segment separately connected to one Motor Module
●
For stator segments with a current demand higher than 66 A:
Single conductor cables to connect the power and to connect the temperature sensors for
each stator segment
For stator segments with a current demand up to 66 A:
Combination cables to connect the power and the temperature sensors for each stator
segment
●
5 TM120 Terminal Modules for
–
Temperature sensor evaluation
–
Protective separation
●
1 SMC20 Sensor Module Cabinet-Mounted to connect the encoder and to evaluate the
encoder signal
●
Internal encoder signal splitting with OA SERVCOUP
Содержание SIMOTICS-T 1FW68
Страница 1: ......
Страница 2: ......
Страница 10: ...Introduction 1FW68 radial segment motors 10 Configuration Manual 04 2017 6SN1197 0AE02 0BP1 ...
Страница 14: ...Table of contents 1FW68 radial segment motors 14 Configuration Manual 04 2017 6SN1197 0AE02 0BP1 ...
Страница 114: ...Configuring 5 2 Mounting 1FW68 radial segment motors 114 Configuration Manual 04 2017 6SN1197 0AE02 0BP1 ...
Страница 132: ...Preparation for use 7 2 Storage 1FW68 radial segment motors 132 Configuration Manual 04 2017 6SN1197 0AE02 0BP1 ...
Страница 179: ......
Страница 180: ......