1LE7
4
A5E36065207, 04/2018
3.1.2
CE marking
Use of machines without CE marking
Machines without CE marking are intended for operation outside the European Economic Area (EEA). Do not use any
machines without a CE marking in the EEA!
3.2
Design
3.2.1
Machine design
Machines of this series are low-voltage three-phase induction or reluctance-synchronous machines with a cylindrical shaft
end and keyway. They can be supplied as single-speed machines with different efficiency classes or as pole changing
machines for several speeds.
In the case of machines with feet (IM B3 type of construction), the feet are cast.
3.2.2
Regulations
The regulations and standards used as the basis for designing and testing this machine are stamped on the rating plate. The
machine design basically complies with the following standards:
Table 3-1
Applicable general regulations
Feature
Standard
Dimensioning and operating behavior
EN / IEC 60034-1
IS 12615, IS/IEC 60034-1
Procedure for determining the losses and the efficiency of rotat-
ing electrical machines and inspections
EN / IEC 60034-2-1
IS 12615
Degree of protection
EN / IEC 60034-5
Cooling
EN / IEC 60034-6
Type of construction
EN / IEC 60034-7
IS 2253
Maße von Drehstrom-Asynchronmotoren für Fußmontage
Dimensions of three phase foot mounted induction motors
IS 1231
Maße von Drehstrom-Asynchronmotore für Flanschmontage
Dimensions of three phase flange mounted induction motors
IS 2223
Terminal markings and direction of rotation
EN / IEC 60034-8
Starting characteristics of rotating electrical machines
EN / IEC 60034-12
Vibration severity grades
EN / IEC 60034-14
IS 12075
Efficiency classification of three-phase squirrel-cage induction
motors
EN / IEC 60034-30 -1
IS 12615
IEC standard voltages
IEC 60038
Leitfaden für die Erdung
Code of practice for earthing
IS 3043
3.2.3
Cooling and ventilation
Forced ventilation (optional): Type of cooling IC 416 in accordance with EN / IEC 60034-6
Cooling that does not depend on the speed is achieved by means of a unit that is independent of the motor operating state
(forced ventilation). This unit is closed to the outside by a fan cover. It has its own main drive with fan impeller which creates
the cooling air flow required for cooling the motor.
See also
Commissioning an external fan (Page 22)
Содержание Simotics SD 1LE7
Страница 1: ......
Страница 2: ......
Страница 35: ...1LE7 A5E36065207 04 2018 33 10 2 Exploded drawing Size 71 90 ...
Страница 36: ...1LE7 34 A5E36065207 04 2018 Size 100 132 ...
Страница 37: ...1LE7 A5E36065207 04 2018 35 Size 160 225 ...
Страница 38: ...1LE7 36 A5E36065207 04 2018 Size 250 315 ...
Страница 43: ......
Страница 44: ......