● Check the correct functioning of the brakes or backstops.
● Set the values for "Alarm" and "Shutdown" at the monitoring devices.
● Carefully ensure that temperature-sensitive parts and components, e.g. cables are not in
contact with the machine enclosure.
See also
Converter operation
● If the motor design requires connection to a specific converter type, carefully check the
supplementary data on the rating plate/supplementary plate.
● Ensure that the converter is correctly parameterized. Depending on the design, you will
find some parameterization data on the rating plate of the machine. Further information is
provided in the converter documentation. If necessary, contact the Service Center.
● Check that the supplementary equipment and devices to monitor the machine are correctly
connected and are functioning correctly.
● In continuous operation, carefully ensure that the motor cannot exceed the specified upper
speed limit n
max
or fall below the lower speed limit n
min
.
The permissible acceleration time to the limit speed n
min
depends on the parameter
assignment.
● The bearing insulation should be implemented as shown on the plates.
● If the machine can be driven by the mechanical system, then protect the converter DC link
voltage against overvoltage conditions: Limit the field-weakening operation to 120%.
The machine will be destroyed if it is directly connected to the line supply. Only operate the
machine using a converter.
Cooling
● Check that the machine cooling is available for commissioning.
Cooling water supply
● The cooling water supply is connected and ready for operation.
● The cooling water supply is switched on. The data can be found on the rating plate.
● Cooling water is available in the configured quality and quantity.
7.3
Greasing the roller bearings prior to commissioning
The following information assumes that the specified storage conditions have been complied
with.
Start-up
7.3 Greasing the roller bearings prior to commissioning
SIMOTICS HT Series HT-direct 1FW4...1......A
Operating Instructions 11/2018
81
Содержание SIMOTICS HT Series
Страница 2: ...13 11 2018 16 25 V5 00 ...
Страница 10: ...Table of contents SIMOTICS HT Series HT direct 1FW4 1 A 10 Operating Instructions 11 2018 ...
Страница 26: ...Description SIMOTICS HT Series HT direct 1FW4 1 A 26 Operating Instructions 11 2018 ...
Страница 62: ...Assembly 5 6 Insulated bearings SIMOTICS HT Series HT direct 1FW4 1 A 62 Operating Instructions 11 2018 ...
Страница 108: ...Maintenance 9 2 Corrective Maintenance SIMOTICS HT Series HT direct 1FW4 1 A 108 Operating Instructions 11 2018 ...
Страница 116: ...Disposal 11 7 Disposal of components SIMOTICS HT Series HT direct 1FW4 1 A 116 Operating Instructions 11 2018 ...
Страница 118: ...Service and Support SIMOTICS HT Series HT direct 1FW4 1 A 118 Operating Instructions 11 2018 ...
Страница 122: ...Quality documents SIMOTICS HT Series HT direct 1FW4 1 A 122 Operating Instructions 11 2018 ...
Страница 127: ......