The vibration magnitudes must not exceed the limits defined in DIN ISO 10816-3 as shown in
the table below. This will ensure flawless commutation, low brush wear, and long bearing life.
Table 8-1
Vibration magnitude as a function of vibration frequency
Vibration frequency
[Hz]
Vibration magnitudes
Vibration magnitude values
Frame size 280 and lower
Frame size 355 and higher
< 6.3 Hz
Vibration displacement s [mm]
≤ 0,1
≤ 0,16
6.3 to 63 Hz
Vibration speed V
rms
[mm/s]
≤ 2,8
≤ 4,5
> 63 Hz
Vibration acceleration a [m/s
2
]
≤ 1,6
≤ 2,55
If higher levels of vibration than the above specified occur in operation, special measures must
be taken. For more information, please contact your local Siemens sales office.
8.2
Regreasing roller bearings
Refer to the regreasing instructions for the roller bearings on the lubricant plate.
8.3
Deactivating
● If not controlled automatically, switch on the anti-condensation heating if installed. This
prevents damage to the winding insulation.
● If not controlled automatically, switch any external fans and fans off.
8.4
Switching on again after an emergency switching-off
● Check the machine before recommissioning the driven machine after an Emergency Off.
● Eliminate all the causes that have led to the emergency off
8.5
Stoppages
The stoppage is a shutdown for a period of time, during which the machine is stopped but
remains at the location of use.
Under normal ambient conditions, e. g. the stopped machine is not exposed to any vibration,
no increased level of corrosion, etc. in general, the following measures are necessary during
stoppages.
Operation
8.5 Stoppages
SIMOTICS DC 1GG6
Operating Instructions 02/2016
73
Содержание SIMOTICS DC 1GG6
Страница 2: ...08 02 2016 10 27 V4 00 ...
Страница 12: ...Table of contents SIMOTICS DC 1GG6 12 Operating Instructions 02 2016 ...
Страница 14: ...Introduction 1 1 About these instructions SIMOTICS DC 1GG6 14 Operating Instructions 02 2016 ...
Страница 62: ...Electrical connection 6 11 Completing connection work SIMOTICS DC 1GG6 62 Operating Instructions 02 2016 ...
Страница 70: ...Commissioning 7 8 Switch off SIMOTICS DC 1GG6 70 Operating Instructions 02 2016 ...
Страница 82: ...Operation 8 9 Faults SIMOTICS DC 1GG6 82 Operating Instructions 02 2016 ...
Страница 104: ...Maintenance 9 2 Repair SIMOTICS DC 1GG6 104 Operating Instructions 02 2016 ...
Страница 138: ...Service and Support SIMOTICS DC 1GG6 138 Operating Instructions 02 2016 ...
Страница 142: ...Quality documents SIMOTICS DC 1GG6 142 Operating Instructions 02 2016 ...
Страница 148: ...Checklists D 4 Inspection when the motor is running SIMOTICS DC 1GG6 148 Operating Instructions 02 2016 ...
Страница 152: ...W Wall face 39 Wall mounting 39 Water drain holes 45 Index SIMOTICS DC 1GG6 152 Operating Instructions 02 2016 ...
Страница 153: ......
Страница 154: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...