CAUTION
Dust disturbances when working with compressed air
When cleaning with compressed air, dust, metal chips, or cleaning agents can be whirled up.
Injuries can result.
When cleaning using compressed air, make sure you use suitable extraction equipment and
wear protective equipment (safety goggles, protective suit, etc.).
NOTICE
Damage to insulation
If metal swarf enters the winding head when cleaning with compressed air, this can damage
the insulation. Clearance and creepage distances can be undershot. This may cause damage
to the machine extending to total failure.
When cleaning with compressed air, ensure there is adequate extraction.
NOTICE
Machine damage caused by foreign bodies
Foreign bodies such as dirt, tools or loose components, such as screws etc., can be left by
accident inside the machine after maintenance is performed. These can cause short circuits,
reduce the performance of the cooling system or increase noise in operation. They can also
damage the machine.
● When carrying out maintenance work, make sure that no foreign bodies are left in or on
the machine.
● Securely attach all loose parts again once you have completed the maintenance
procedures.
● Carefully remove any dirt.
Note
Operating conditions and characteristics can vary widely. For this reason, only general
intervals for inspection and maintenance measures can be specified here.
9.1.1
Initial inspection
● Perform the initial inspection after installing or commissioning the motor. Normally the initial
inspection is only necessary after approx. 500 hours of operation.
● Perform follow-up inspections after every approx. 2,000 hours of operation.
Maintenance
9.1 Inspection and maintenance
SIMOTICS DC 1GG6
84
Operating Instructions 02/2016
Содержание SIMOTICS DC 1GG6
Страница 2: ...08 02 2016 10 27 V4 00 ...
Страница 12: ...Table of contents SIMOTICS DC 1GG6 12 Operating Instructions 02 2016 ...
Страница 14: ...Introduction 1 1 About these instructions SIMOTICS DC 1GG6 14 Operating Instructions 02 2016 ...
Страница 62: ...Electrical connection 6 11 Completing connection work SIMOTICS DC 1GG6 62 Operating Instructions 02 2016 ...
Страница 70: ...Commissioning 7 8 Switch off SIMOTICS DC 1GG6 70 Operating Instructions 02 2016 ...
Страница 82: ...Operation 8 9 Faults SIMOTICS DC 1GG6 82 Operating Instructions 02 2016 ...
Страница 104: ...Maintenance 9 2 Repair SIMOTICS DC 1GG6 104 Operating Instructions 02 2016 ...
Страница 138: ...Service and Support SIMOTICS DC 1GG6 138 Operating Instructions 02 2016 ...
Страница 142: ...Quality documents SIMOTICS DC 1GG6 142 Operating Instructions 02 2016 ...
Страница 148: ...Checklists D 4 Inspection when the motor is running SIMOTICS DC 1GG6 148 Operating Instructions 02 2016 ...
Страница 152: ...W Wall face 39 Wall mounting 39 Water drain holes 45 Index SIMOTICS DC 1GG6 152 Operating Instructions 02 2016 ...
Страница 153: ......
Страница 154: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...