![Siemens Simatic series Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/siemens/simatic-series/simatic-series_operating-instructions-manual_378294077.webp)
Expanding and assigning parameters to the device
6.4 Memory expansion
SIMATIC IPC547G
Operating Instructions, 04/2020, A5E49948632-AA
77
Requirement
●
The front door is open; see "Opening the front door (Page 76)".
●
The device is fully disconnected from the mains voltage; see section "Switching off the
●
All connection cables are unplugged.
●
T10 screwdriver
Procedure
1.
Remove the captive screw.
2.
Push the enclosure cover back.
3.
Lift up and remove the enclosure cover.
6.4
Memory expansion
Depending on the device version there are two or four slots for memory modules on the
motherboard. You can expand the memory up to 64 GB, for devices with motherboard
D3445-S up to 32 GB. Of which 3.2 GB can be used in a 32-bit operating system.
The following memory modules can be installed:
Motherboard Number of slots
2 GB *
4 GB
8 GB *
16 GB *
Max. possible
D3445
2
-
X
X
X
32 GB
D3446
4
-
X
X
X
64 GB
* The following memory module types are approved: DDR4 SDRAM PC4-2400T/s
A detailed description of possible memory expansion options is available in the manual of
the motherboard on the supplied "Documentation and Drivers" DVD.
Содержание Simatic series
Страница 30: ...Overview 1 3 Accessories SIMATIC IPC547G 30 Operating Instructions 04 2020 A5E49948632 AA ...
Страница 38: ...Safety instructions 2 2 Notes on use SIMATIC IPC547G 38 Operating Instructions 04 2020 A5E49948632 AA ...
Страница 180: ...List of abbreviations SIMATIC IPC547G 180 Operating Instructions 04 2020 A5E49948632 AA ...
Страница 194: ...Index SIMATIC IPC547G 194 Operating Instructions 04 2020 A5E49948632 AA ...