Installing and connecting the device
3.3 Connecting the device
SIMATIC IPC547G
50
Operating Instructions, 04/2020, A5E49948632-AA
Connecting a redundant power supply
1.
Make sure that the on/off switch
②
is in the '0'
position.
2.
Connect a power cable to the two sockets
③
.
3.
Switch on the two on/off switches
②
.
The "Power" LEDs
①
on the power supply
modules light up green.
Note:
If only one of the power supply modules works,
a warning signal sounds. You turn off the
warning signal by pressing the
①
alarm reset
button on the working power supply module.
To prevent unintentional removal of the power cable, you can secure the power plug as
follows:
1.
Remove the retaining screws
④
.
2.
Screw on the latch for the power plug
⑤
on the
thread
④
.
3.3.4
Connecting peripheral equipment
Note
Observe suitability for industrial applications
Only connect I/O devices that are suitable for industrial applications in accordance with
EN IEC 61000-6-2.
Note
I/O devices capable of hot-plugging (USB)
Hot-plug I/O devices (USB) may be connected while the PC is in operation.
NOTICE
Non-hot-plug I/O devices
I/O devices that do not support hot-plugging may not be connected until the device is
powered off. Strictly adhere to the specifications in the I/O manuals.
Содержание Simatic series
Страница 30: ...Overview 1 3 Accessories SIMATIC IPC547G 30 Operating Instructions 04 2020 A5E49948632 AA ...
Страница 38: ...Safety instructions 2 2 Notes on use SIMATIC IPC547G 38 Operating Instructions 04 2020 A5E49948632 AA ...
Страница 180: ...List of abbreviations SIMATIC IPC547G 180 Operating Instructions 04 2020 A5E49948632 AA ...
Страница 194: ...Index SIMATIC IPC547G 194 Operating Instructions 04 2020 A5E49948632 AA ...