Configuring
5.1 Assigning the IP address / device name
SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
25
10.In the "PG/PC interface" drop-down list in the "Online access" area, select the network
adapter via which the reader is connected to the PG/PC.
11.Click the "Update list" button to display all reachable devices in the network.
12.Select the required node from the list.
13.Click the "Assign name" button to assign the PROFINET device name to the reader.
Result: The reader is assigned the configured PROFINET device name from the project.
Note
Assigning a device name when replacing a module
When you replace a module, you can assign the device names automatically. You will find
more information on this in the section "Module replacement (Page 99)".
Device flash test using the TIA Portal
Using the node flash test, you can identify the reader quickly and simply by having the LEDs
of the device flash. This function is especially helpful if multiple devices are connected to the
controller. In this case, compare the MAC address of the device with the MAC address
displayed and then select the desired device.
Proceed as follows to identify the relevant device using the flash test:
1.
In the project tree, select the menu command "Online access > Your online access > Update
accessible devices".
The available devices are displayed.
2.
Select the required reader and click the entry "Online & Diagnostics" in the folder of the
selected device.
3.
Select the option "Functions > Assign name".
4.
Click the "Flash LED" button.
Reaction: The LEDs on the selected reader flash.
5.
Click the "Flash LED" button again to stop the flashing.