Hardware Information
Release 11/02
7-13
SIMATIC Panel PC 870 Computing Unit, Equipment Manual
Ethernet RJ45 connection, X700
Connector
Pin
No.
Short
Name
Meaning
Input /
Output
1
TD+
Transmission
2
TD–
Transmission
data
Output
3
RD+
Received data
Input
LED
green
LED
yellow
4, 5 *
SYMR
internally
terminated with
75
Ω
-
6
Received data
Input
7, 8 *
SYMT
internally
terminated with
75
Ω
-
1
8
S
Shield
-
LED
yellow
Connection
-
LED green Activity
-
*
Not required for data transmission
VGA port, X303
The VGA socket on the computer unit is assigned as follows:
Connector
Pin
No.
Designation
Meaning
Input/
Output
1
R
Red
2
G
Green
Output
3
B
Blue
4
NC
Not Connected
-
5
1
6
11
6
7
GND
Ground
–
8
9
5 V
+ 5 V fused
Output
5
10
15
10
GND
Ground
–
15
11
NC
Not Connected
-
12
DDC_DAT
DDC data line
Input / output
13
EXT_H
Horiz. synchron. signal
14
EXT_V
Vert. synchron. signal
Output
15
DDC_CLK
DDC clock line
Input / output
Содержание Simatic PC Panel PC 870
Страница 4: ...Chapter For your notes ...
Страница 12: ...Contents Release 11 02 xii SIMATIC Panel PC 870 Computing Unit Equipment Manual ...
Страница 94: ...Fault Diagnosis Release 11 02 6 10 SIMATIC Panel PC 870 Computing Unit Equipment Manual ...
Страница 130: ...Hardware Information Release 11 02 7 36 SIMATIC Panel PC 870 Computing Unit Equipment Manual ...
Страница 154: ...Index Release 11 02 Index 4 SIMATIC Panel PC 870 Computing Unit Equipment Manual ...