installing and removing
5
5.1
Safety during mounting
Safety notices
When installing the device, keep to the safety notices listed below.
WARNING
If a device is operated in an ambient temperature of more than 55 °C, the temperature of the
device enclosure may be higher than 70 °C. The device must therefore be installed so that it is
only accessible to service personnel or users that are aware of the reason for restricted access
and of the required safety measures at an ambient temperature higher than 55 to 70 °C.
WARNING
If the device is installed in a cabinet, the inner temperature of the cabinet corresponds to the
ambient temperature of the device.
WARNING
If the temperature of the cable or housing socket exceeds 70 °C or the temperature at the
branching points of the cables exceeds 80 °C, special precautions must be taken. If the device
is operated at max. ambient temperature, only use cables with permitted maximum operating
temperature of at least 90 ℃.
NOTICE
Improper mounting
Improper mounting may damage the device or impair its operation.
• Before mounting the device, always ensure that there is no visible damage to the device.
• Mount the device using suitable tools. Observe the information in the respective section
about mounting.
SCALANCE XCM-300
Product
Manual, 04/2022, C79000-G8976-C585-01
31
Содержание SIMATIC NET SCALANCE XCM-300
Страница 6: ...Table of contents 6 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 12: ...Safety notices 12 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 58: ...Maintenance and cleaning 58 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 80: ...Certifications and approvals 80 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...