5.8
Connecting a SCALANCE XCM-300 with a SCALANCE LPE
Position
The following figure shows the elements required to connect a SCALANCE XCM-300 with a
SCALANCE LPE.
①
Lock (on the device rear of the SCALANCE XCM-300)
②
Centering pin
③
Opening to hold a centering pin
④
Multipole connector for connection to the function extender interface
This connector is closed with a cover in the delivery state.
⑤
Function extender interface
This interface is closed with a cover in the delivery state.
Types of installation
You have the following options for connecting the devices:
• You can connect the devices and mount them together on a DIN or S7 standard rail.
• You can mount a device on a DIN rail or S7 mounting rail and connect it later.
Note
For mounting on a rail as well as for removing from the rail, plan enough space between the
devices, see section "Dimension drawings (Page 67)".
Connecting devices
NOTICE
Danger of damage to property
The two devices cannot be connected during operation. Disconnect the two devices from the
power supply before connecting the devices.
installing and removing
5.8 Connecting a SCALANCE XCM-300 with a SCALANCE LPE
SCALANCE XCM-300
Product
Manual, 04/2022, C79000-G8976-C585-01
41
Содержание SIMATIC NET SCALANCE XCM-300
Страница 6: ...Table of contents 6 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 12: ...Safety notices 12 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 58: ...Maintenance and cleaning 58 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...
Страница 80: ...Certifications and approvals 80 SCALANCE XCM 300 Product Manual 04 2022 C79000 G8976 C585 01 ...